    A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact

    Source: Journal of Biomechanical Engineering:;2002:;volume( 124 ):;issue: 003::page 273
    Author:
    Tammy L. Haut Donahue
    ,
    M. L. Hull
    ,
    Mark M. Rashid
    ,
    Associate Professor of Civil Engineering
    ,
    Christopher R. Jacobs
    ,
    Associate Professor of Orthopaedics
    DOI: 10.1115/1.1470171
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (i.e., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.
    keyword(s): Pressure , Solid models , Stress , Bone , Finite element analysis , Finite element model , Cartilage , Knee , Force , Lasers , Biological tissues , Rotation AND Errors ,
    • Download: (262.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/126391
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorTammy L. Haut Donahue
    contributor authorM. L. Hull
    contributor authorMark M. Rashid
    contributor authorAssociate Professor of Civil Engineering
    contributor authorChristopher R. Jacobs
    contributor authorAssociate Professor of Orthopaedics
    date accessioned2017-05-09T00:06:50Z
    date available2017-05-09T00:06:50Z
    date copyrightJune, 2002
    date issued2002
    identifier issn0148-0731
    identifier otherJBENDY-26248#273_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/126391
    description abstractAs a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (i.e., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Finite Element Model of the Human Knee Joint for the Study of Tibio-Femoral Contact
    typeJournal Paper
    journal volume124
    journal issue3
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.1470171
    journal fristpage273
    journal lastpage280
    identifier eissn1528-8951
    keywordsPressure
    keywordsSolid models
    keywordsStress
    keywordsBone
    keywordsFinite element analysis
    keywordsFinite element model
    keywordsCartilage
    keywordsKnee
    keywordsForce
    keywordsLasers
    keywordsBiological tissues
    keywordsRotation AND Errors
    treeJournal of Biomechanical Engineering:;2002:;volume( 124 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian