    The Experimental Study of Matching Between Centrifugal Compressor Impeller and Diffuser

    Source: Journal of Turbomachinery:;1999:;volume( 121 ):;issue: 001::page 113
    Author:
    H. Tamaki
    ,
    H. Nakao
    ,
    M. Saito
    DOI: 10.1115/1.2841218
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The centrifugal compressor for a marine use turbocharger with its design pressure ratio of 3.2 was tested with a vaneless diffuser and various vaned diffusers. Vaned diffusers were chosen to cover impeller operating range as broad as possible. The analysis of the static pressure ratio in the impeller and the diffusing system, consisting of the diffuser and scroll, showed that there were four possible combinations of characteristics of impeller pressure ratio and diffusing system pressure ratio, The flow rate, QP , where the impeller achieved maximum static pressure ratio, was surge flow rate of the centrifugal compressor determined by the critical flow rate. In order to operate the compressor at a rate lower than QP , the diffusing system, whose pressure recovery factor was steep negative slope near QP , was needed. When the diffuser throat area was less than a certain value, the compressor efficiency deteriorated; however, the compressor stage pressure ratio was almost constant. In this study, by reducing the diffuser throat area, the compressor could be operated at a flow rate less than 40 percent of its design flow rate. Analysis of the pressure ratio in the impeller and diffusing systems at design and off-design speeds showed that the irregularities in surge line occurred when the component that controlled the negative slope on the compressor stage pressure ratio changed.
    keyword(s): Diffusers , Compressor impellers , Pressure , Compressors , Impellers , Flow (Dynamics) , Design , Surges AND Vaneless diffusers ,
    • Download: (784.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Experimental Study of Matching Between Centrifugal Compressor Impeller and Diffuser

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/123067
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorH. Tamaki
    contributor authorH. Nakao
    contributor authorM. Saito
    date accessioned2017-05-09T00:01:21Z
    date available2017-05-09T00:01:21Z
    date copyrightJanuary, 1999
    date issued1999
    identifier issn0889-504X
    identifier otherJOTUEI-28668#113_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/123067
    description abstractThe centrifugal compressor for a marine use turbocharger with its design pressure ratio of 3.2 was tested with a vaneless diffuser and various vaned diffusers. Vaned diffusers were chosen to cover impeller operating range as broad as possible. The analysis of the static pressure ratio in the impeller and the diffusing system, consisting of the diffuser and scroll, showed that there were four possible combinations of characteristics of impeller pressure ratio and diffusing system pressure ratio, The flow rate, QP , where the impeller achieved maximum static pressure ratio, was surge flow rate of the centrifugal compressor determined by the critical flow rate. In order to operate the compressor at a rate lower than QP , the diffusing system, whose pressure recovery factor was steep negative slope near QP , was needed. When the diffuser throat area was less than a certain value, the compressor efficiency deteriorated; however, the compressor stage pressure ratio was almost constant. In this study, by reducing the diffuser throat area, the compressor could be operated at a flow rate less than 40 percent of its design flow rate. Analysis of the pressure ratio in the impeller and diffusing systems at design and off-design speeds showed that the irregularities in surge line occurred when the component that controlled the negative slope on the compressor stage pressure ratio changed.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Experimental Study of Matching Between Centrifugal Compressor Impeller and Diffuser
    typeJournal Paper
    journal volume121
    journal issue1
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.2841218
    journal fristpage113
    journal lastpage118
    identifier eissn1528-8900
    keywordsDiffusers
    keywordsCompressor impellers
    keywordsPressure
    keywordsCompressors
    keywordsImpellers
    keywordsFlow (Dynamics)
    keywordsDesign
    keywordsSurges AND Vaneless diffusers
    treeJournal of Turbomachinery:;1999:;volume( 121 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian