    The Effect of Graft Caliber Upon Wall Shear Within in Vivo Distal Vascular Anastomoses

    Source: Journal of Biomechanical Engineering:;1999:;volume( 121 ):;issue: 001::page 79
    Author:
    R. S. Keynton
    ,
    M. M. Evancho
    ,
    S. E. Rittgers
    ,
    R. L. Sims
    DOI: 10.1115/1.2798047
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Wall shear has been widely implicated as a contributing factor in the development of intimal hyperplasia in the anastomoses of chronic arterial bypass grafts. Earlier studies have been restricted to either: (1) in vitro or computer simulation models detailing the complex hemodynamics within an anastomosis without corresponding biological responses, or (2) in vivo models that document biological effects with only approximate wall shear information. Recently, a specially designed pulse ultrasonic Doppler wall shear rate (PUDWSR) measuring device has made it possible to obtain three near-wall velocity measurements nonintrusively within 1.05 mm of the vessel luminal surface from which wall shear rates (WSRs) were derived. It was the purpose of this study to evaluate the effect of graft caliber, a surgically controllable variable, upon local hemodynamics, which, in turn, play an important role in the eventual development of anastomotic hyperplasia. Tapered (4–7 mm I.D.) 6-cm-long grafts were implanted bilaterally in an end-to-side fashion with 30 deg proximal and distal anastomoses to bypass occluded common carotid arteries of 16 canines. The bypass grafts were randomly paired in contralateral vessels and placed such that the graft-to-artery diameter ratio, DR, at the distal anastomosis was either 1.0 or 1.5. For all grafts, the average Re was 432 ± 112 and the average Womersley parameter,α, was 3.59 ± 0.39 based on artery diameter. There was a sharp skewing of flow toward the artery floor with the development of a stagnation point whose position varied with time (up to two artery diameters) and DR (generally more downstream for DR = 1.0). Mean WSRs along the artery floor for DR = 1.0 and 1.5 were found to range sharply from moderate to high retrograde values (589 s−1 and 1558 s−1 , respectively) upstream to high antegrade values (2704 s−1 and 2302 s−1 , respectively) immediately downstream of the stagnation point. Although there were no overall differences in mean and peak WSRs between groups, there were significant differences (p < 0.05) in oscillatory WSRs as well as in the absolute normalized mean and peak WSRs between groups. There were also significant differences (p < 0.05) in mean and peak WSRs with respect to axial position along the artery floor for both DR cases. In conclusion, WSR varies widely (1558 s−1 retrograde to 2704 s−1 antegrade) within end-to-side distal graft anastomoses, particularly along the artery floor, and may play a role in the development of intimal hyperplasia through local alteration of mass transport and mechano-signal transduction within the endothelium.
    keyword(s): Shear (Mechanics) , Hemodynamics , Vessels , Carotid arteries , Signals , Velocity measurement , Surgery , Flow (Dynamics) AND Computer simulation ,
    • Download: (1.150Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Effect of Graft Caliber Upon Wall Shear Within in Vivo Distal Vascular Anastomoses

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/121841
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorR. S. Keynton
    contributor authorM. M. Evancho
    contributor authorS. E. Rittgers
    contributor authorR. L. Sims
    date accessioned2017-05-08T23:59:04Z
    date available2017-05-08T23:59:04Z
    date copyrightFebruary, 1999
    date issued1999
    identifier issn0148-0731
    identifier otherJBENDY-26012#79_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/121841
    description abstractWall shear has been widely implicated as a contributing factor in the development of intimal hyperplasia in the anastomoses of chronic arterial bypass grafts. Earlier studies have been restricted to either: (1) in vitro or computer simulation models detailing the complex hemodynamics within an anastomosis without corresponding biological responses, or (2) in vivo models that document biological effects with only approximate wall shear information. Recently, a specially designed pulse ultrasonic Doppler wall shear rate (PUDWSR) measuring device has made it possible to obtain three near-wall velocity measurements nonintrusively within 1.05 mm of the vessel luminal surface from which wall shear rates (WSRs) were derived. It was the purpose of this study to evaluate the effect of graft caliber, a surgically controllable variable, upon local hemodynamics, which, in turn, play an important role in the eventual development of anastomotic hyperplasia. Tapered (4–7 mm I.D.) 6-cm-long grafts were implanted bilaterally in an end-to-side fashion with 30 deg proximal and distal anastomoses to bypass occluded common carotid arteries of 16 canines. The bypass grafts were randomly paired in contralateral vessels and placed such that the graft-to-artery diameter ratio, DR, at the distal anastomosis was either 1.0 or 1.5. For all grafts, the average Re was 432 ± 112 and the average Womersley parameter,α, was 3.59 ± 0.39 based on artery diameter. There was a sharp skewing of flow toward the artery floor with the development of a stagnation point whose position varied with time (up to two artery diameters) and DR (generally more downstream for DR = 1.0). Mean WSRs along the artery floor for DR = 1.0 and 1.5 were found to range sharply from moderate to high retrograde values (589 s−1 and 1558 s−1 , respectively) upstream to high antegrade values (2704 s−1 and 2302 s−1 , respectively) immediately downstream of the stagnation point. Although there were no overall differences in mean and peak WSRs between groups, there were significant differences (p < 0.05) in oscillatory WSRs as well as in the absolute normalized mean and peak WSRs between groups. There were also significant differences (p < 0.05) in mean and peak WSRs with respect to axial position along the artery floor for both DR cases. In conclusion, WSR varies widely (1558 s−1 retrograde to 2704 s−1 antegrade) within end-to-side distal graft anastomoses, particularly along the artery floor, and may play a role in the development of intimal hyperplasia through local alteration of mass transport and mechano-signal transduction within the endothelium.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Effect of Graft Caliber Upon Wall Shear Within in Vivo Distal Vascular Anastomoses
    typeJournal Paper
    journal volume121
    journal issue1
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2798047
    journal fristpage79
    journal lastpage88
    identifier eissn1528-8951
    keywordsShear (Mechanics)
    keywordsHemodynamics
    keywordsVessels
    keywordsCarotid arteries
    keywordsSignals
    keywordsVelocity measurement
    keywordsSurgery
    keywordsFlow (Dynamics) AND Computer simulation
    treeJournal of Biomechanical Engineering:;1999:;volume( 121 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian