Show simple item record

contributor authorH. J. Weigl
contributor authorM. M. Bright
contributor authorA. J. Strazisar
contributor authorJ. D. Paduano
contributor authorL. G. Fréchette
contributor authorA. H. Epstein
contributor authorE. M. Greitzer
date accessioned2017-05-08T23:58:04Z
date available2017-05-08T23:58:04Z
date copyrightOctober, 1998
date issued1998
identifier issn0889-504X
identifier otherJOTUEI-28667#625_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/121258
description abstractRotating stall and surge have been stabilized in a transonic single-stage axial compressor using active feedback control. The control strategy is to sense upstream wall static pressure patterns and feed back the signal to an annular array of twelve separately modulated air injectors. At tip relative Mach numbers of 1.0 and 1.5 the control achieved 11 and 3.5 percent reductions in stalling mass flow, respectively, with injection adding 3.6 percent of the design compressor mass flow. The aerodynamic effects of the injection have also been examined. At a tip Mach number, Mtip , of 1.0, the stall inception dynamics and effective active control strategies are similar to results for low-speed axial compressors. The range extension was achieved by individually damping the first and second spatial harmonics of the prestall perturbations using constant gain feedback. At a Mtip of 1.5 (design rotor speed), the prestall dynamics are different than at the lower speed. Both one-dimensional (surge) and two-dimensional (rotating stall) perturbations needed to be stabilized to increase the compressor operating range. At design speed, the instability was initiated by approximately ten rotor revolutions of rotating stall followed by classic surge cycles. In accord with the results from a compressible stall inception analysis, the zeroth, first, and second spatial harmonics each include more than one lightly damped mode, which can grow into the large amplitude instability. Forced response testing identified several modes traveling up to 150 percent of rotor speed for the first three spatial harmonics; simple constant gain control cannot damp all of these modes and thus cannot stabilize the compressor at this speed. A dynamic, model-based robust controller was therefore used to stabilize the multiple modes that comprise the first three harmonic perturbations in this transonic region of operation.
publisherThe American Society of Mechanical Engineers (ASME)
title1997 Best Paper Award—Controls and Diagnostics Committee: Active Stabilization of Rotating Stall and Surge in a Transonic Single-Stage Axial Compressor
typeJournal Paper
journal volume120
journal issue4
journal titleJournal of Turbomachinery
identifier doi10.1115/1.2841772
journal fristpage625
journal lastpage636
identifier eissn1528-8900
keywordsCompressors
keywordsSurges
keywordsRotors
keywordsDesign
keywordsDynamics (Mechanics)
keywordsFlow (Dynamics)
keywordsMach number
keywordsFeedback
keywordsStall inception
keywordsTravel
keywordsSignals
keywordsTesting
keywordsCycles
keywordsControl equipment
keywordsPressure
keywordsEjectors AND Damping
treeJournal of Turbomachinery:;1998:;volume( 120 ):;issue: 004
contenttypeFulltext