    NDE of a Crack by Using Closely Coupled Probes for DCPD Technique

    Source: Journal of Pressure Vessel Technology:;1996:;volume( 118 ):;issue: 002::page 198
    Author:
    M. Saka
    ,
    A. Oouchi
    ,
    H. Abé
    DOI: 10.1115/1.2842181
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In order to enhance the sensitivity of the d-c potential drop technique, the principle of a technique using the closely coupled probes is proposed. A calibration equation for this technique is derived, where the path-independent integral je for electric crack problems is utilized. Experiments on laboratory specimens are discussed which validate the use of the calibration equation for the nondestructive evaluation of cracks. It is shown that the sensitivity of the present method using closely coupled probes is higher than that of the usual method using a uniform current flow in the region far from the crack.
    keyword(s): Nondestructive evaluation , Fracture (Materials) , Probes , Calibration , Equations , Drops AND Flow (Dynamics) ,
    • Download: (631.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      NDE of a Crack by Using Closely Coupled Probes for DCPD Technique

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/117562
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorM. Saka
    contributor authorA. Oouchi
    contributor authorH. Abé
    date accessioned2017-05-08T23:51:23Z
    date available2017-05-08T23:51:23Z
    date copyrightMay, 1996
    date issued1996
    identifier issn0094-9930
    identifier otherJPVTAS-28368#198_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/117562
    description abstractIn order to enhance the sensitivity of the d-c potential drop technique, the principle of a technique using the closely coupled probes is proposed. A calibration equation for this technique is derived, where the path-independent integral je for electric crack problems is utilized. Experiments on laboratory specimens are discussed which validate the use of the calibration equation for the nondestructive evaluation of cracks. It is shown that the sensitivity of the present method using closely coupled probes is higher than that of the usual method using a uniform current flow in the region far from the crack.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNDE of a Crack by Using Closely Coupled Probes for DCPD Technique
    typeJournal Paper
    journal volume118
    journal issue2
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.2842181
    journal fristpage198
    journal lastpage202
    identifier eissn1528-8978
    keywordsNondestructive evaluation
    keywordsFracture (Materials)
    keywordsProbes
    keywordsCalibration
    keywordsEquations
    keywordsDrops AND Flow (Dynamics)
    treeJournal of Pressure Vessel Technology:;1996:;volume( 118 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian