description abstractA noncalorimetric method for measuring the heat-transfer coefficient (UA) of building thermal envelopes is proposed and applied in an indoor test cell. The UA value measured by this method agrees closely with that measured by a calorimetric method. This method creates a Single input and a Single output data Pair (SSP) from the measured data sets by using digital filters. The filter output and physical criteria are used to determine the correct transfer function, which yields the measured UA value. This method seems to have the following advantages over calorimetric methods: it uses shorter measurement times, uses simpler test equipment, and has minimum thermal intrusion on normal operating conditions.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Noncalorimetric Method for Heat-Transfer Coefficient Measurement of Building Thermal Envelopes
typeJournal Paper
journal volume117
journal issue2
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.2870829
journal fristpage108
journal lastpage113
identifier eissn1528-8986
keywordsHeat transfer
keywordsFilters
keywordsTesting equipment AND Transfer functions
treeJournal of Solar Energy Engineering:;1995:;volume( 117 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record