| contributor author | G. E. Weber | |
| contributor author | W. M. Worek | |
| date accessioned | 2017-05-08T23:47:14Z | |
| date available | 2017-05-08T23:47:14Z | |
| date copyright | April, 1995 | |
| date issued | 1995 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-26738#384_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/115326 | |
| description abstract | The application of the Modified Delaware Method, which was developed by Weber and Worek (1994) to evaluate the design performance of a feedwater heater with a short drain cooler, is illustrated. All calculations used in obtaining the heat transfer coefficients and pressure drops in the desuperheating, condensing, and drain cooling zones are shown by applying the method to an actual heater design. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | The Application of a Method to Evaluate the Design Performance of a Feedwater Heater With a Short Drain Cooler | |
| type | Journal Paper | |
| journal volume | 117 | |
| journal issue | 2 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.2814106 | |
| journal fristpage | 384 | |
| journal lastpage | 388 | |
| identifier eissn | 0742-4795 | |
| keywords | Feedwater | |
| keywords | Design | |
| keywords | Pressure drop | |
| keywords | Heat transfer coefficients AND Cooling | |
| tree | Journal of Engineering for Gas Turbines and Power:;1995:;volume( 117 ):;issue: 002 | |
| contenttype | Fulltext | |