YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Flow Structures at the Proximal Side-to-End Anastomosis. Influence of Geometry and Flow Division

    Source: Journal of Biomechanical Engineering:;1995:;volume( 117 ):;issue: 002::page 224
    Author:
    P. E. Hughes
    ,
    T. V. How
    DOI: 10.1115/1.2796005
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Flow structures were visualized in transparent polyurethane models of proximal side-to-end vascular anastomoses, using planar illumination of suspended tracer particles. Both the effects of geometry and flow division were determined under steady and pulsatile flow conditions, for anastomosis angles of 15, 30, and 45 degrees. The flow patterns were highly three-dimensional and were characterized by a series of vortices in the fully occluded distal artery and two helical vortices aligned with the axis of the graft. In steady flow, above a critical Reynolds number, the flow changed from a laminar regime to one displaying time-dependent behavior. In particular, significant fluctuating velocity components were observed in the distal artery and particles were shed periodically from the occluded artery into the graft. Pairs of asymmetric flow patterns were also observed in the graft, before the onset of the time-dependent flow regime. The critical Reynolds number ranged from 427 to 473 and appeared to be independent of anastomosis angle. The presence of a patent distal artery had a significant effect on the overall flow pattern and led to the formation of a large recirculation region at the toe of the anastomosis. The main structures observed in steady flow, such as vortices in the distal artery and helical flow in the graft, were also seen during the pulsatile cycle. However, the secondary flow components in the graft were more pronounced in pulsatile flow particularly during deceleration of the flow waveform. At higher mean Reynolds numbers, there was also a greater mixing between fluid in the occluded arterial section and that in the graft.
    keyword(s): Flow (Dynamics) , Geometry , Vortices , Reynolds number , Pulsatile flow , Particulate matter , Transparency , Urethane elastomers , Fluids , Cycles AND Patents ,
    • Download: (2.228Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Flow Structures at the Proximal Side-to-End Anastomosis. Influence of Geometry and Flow Division

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/115000
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorP. E. Hughes
    contributor authorT. V. How
    date accessioned2017-05-08T23:46:40Z
    date available2017-05-08T23:46:40Z
    date copyrightMay, 1995
    date issued1995
    identifier issn0148-0731
    identifier otherJBENDY-25952#224_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/115000
    description abstractFlow structures were visualized in transparent polyurethane models of proximal side-to-end vascular anastomoses, using planar illumination of suspended tracer particles. Both the effects of geometry and flow division were determined under steady and pulsatile flow conditions, for anastomosis angles of 15, 30, and 45 degrees. The flow patterns were highly three-dimensional and were characterized by a series of vortices in the fully occluded distal artery and two helical vortices aligned with the axis of the graft. In steady flow, above a critical Reynolds number, the flow changed from a laminar regime to one displaying time-dependent behavior. In particular, significant fluctuating velocity components were observed in the distal artery and particles were shed periodically from the occluded artery into the graft. Pairs of asymmetric flow patterns were also observed in the graft, before the onset of the time-dependent flow regime. The critical Reynolds number ranged from 427 to 473 and appeared to be independent of anastomosis angle. The presence of a patent distal artery had a significant effect on the overall flow pattern and led to the formation of a large recirculation region at the toe of the anastomosis. The main structures observed in steady flow, such as vortices in the distal artery and helical flow in the graft, were also seen during the pulsatile cycle. However, the secondary flow components in the graft were more pronounced in pulsatile flow particularly during deceleration of the flow waveform. At higher mean Reynolds numbers, there was also a greater mixing between fluid in the occluded arterial section and that in the graft.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleFlow Structures at the Proximal Side-to-End Anastomosis. Influence of Geometry and Flow Division
    typeJournal Paper
    journal volume117
    journal issue2
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2796005
    journal fristpage224
    journal lastpage236
    identifier eissn1528-8951
    keywordsFlow (Dynamics)
    keywordsGeometry
    keywordsVortices
    keywordsReynolds number
    keywordsPulsatile flow
    keywordsParticulate matter
    keywordsTransparency
    keywordsUrethane elastomers
    keywordsFluids
    keywordsCycles AND Patents
    treeJournal of Biomechanical Engineering:;1995:;volume( 117 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian