Show simple item record

contributor authorM. Shiraishi
contributor authorT. Sato
date accessioned2017-05-08T23:43:15Z
date available2017-05-08T23:43:15Z
date copyrightDecember, 1994
date issued1994
identifier issn0021-8936
identifier otherJAMCAV-26360#850_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/113009
description abstractSwitching phenomenon of the bathtub vortex in a double-orifice water tank is experimentally investigated. This alternation between “vortexflow” and “nonvortex flow” is caused by flow rate differences through the two orifices. The oscillation frequency is experimentally examined by changing the design parameters, such as the orifice size, the distance between two orifices, and the fluid level. A linear relationship is obtained between the frequency and the flow rate difference.
publisherThe American Society of Mechanical Engineers (ASME)
titleSwitching Phenomenon of a Bathtub Vortex
typeJournal Paper
journal volume61
journal issue4
journal titleJournal of Applied Mechanics
identifier doi10.1115/1.2901567
journal fristpage850
journal lastpage854
identifier eissn1528-9036
keywordsVortices
keywordsFlow (Dynamics)
keywordsOrifices
keywordsWater
keywordsFluids
keywordsDesign AND Oscillations
treeJournal of Applied Mechanics:;1994:;volume( 061 ):;issue: 004