| contributor author | G. Gerbert | |
| contributor author | Håkan Båstedt | |
| date accessioned | 2017-05-08T23:41:58Z | |
| date available | 2017-05-08T23:41:58Z | |
| date copyright | December, 1993 | |
| date issued | 1993 | |
| identifier issn | 1050-0472 | |
| identifier other | JMDEDB-27611#701_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/112286 | |
| description abstract | Externally loaded bolt joints of different design are investigated. The bolt load is substantially lower than that predicted by the mounting stiffnesses of bolt and abutment. A load application fraction n is introduced in VDI 2230 and some thumb rules are suggested. New fractions are determined which are much lower than the suggested ones. It appears that the application fraction n is almost independent of the location of the external load in practical design but it is influenced by the layout of the bolt joint. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Centrically Loaded Bolt Joints | |
| type | Journal Paper | |
| journal volume | 115 | |
| journal issue | 4 | |
| journal title | Journal of Mechanical Design | |
| identifier doi | 10.1115/1.2919257 | |
| journal fristpage | 701 | |
| journal lastpage | 705 | |
| identifier eissn | 1528-9001 | |
| keywords | Stress AND Design | |
| tree | Journal of Mechanical Design:;1993:;volume( 115 ):;issue: 004 | |
| contenttype | Fulltext | |