| contributor author | J. John | |
| contributor author | T. Schobeiri | |
| date accessioned | 2017-05-08T23:41:45Z | |
| date available | 2017-05-08T23:41:45Z | |
| date copyright | March, 1993 | |
| date issued | 1993 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-27073#148_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/112188 | |
| description abstract | This paper presents an improved method of calibrating hot-film X-probes in incompressible flow. The yaw response of a hot-film X-probe was investigated for different velocities and found to be strongly velocity dependent at low velocities. A simple relation was developed to correct for the variation of yaw response at low velocities. The method using the yaw correction is compared with the single-velocity yaw calibration method. The correction to the yaw response considerably improves accuracy at low velocities. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Simple and Accurate Method of Calibrating X-Probes | |
| type | Journal Paper | |
| journal volume | 115 | |
| journal issue | 1 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.2910098 | |
| journal fristpage | 148 | |
| journal lastpage | 152 | |
| identifier eissn | 1528-901X | |
| keywords | Probes | |
| keywords | Yaw | |
| keywords | Flow (Dynamics) AND Calibration | |
| tree | Journal of Fluids Engineering:;1993:;volume( 115 ):;issue: 001 | |
| contenttype | Fulltext | |