description abstract | This paper presents an improved method of calibrating hot-film X-probes in incompressible flow. The yaw response of a hot-film X-probe was investigated for different velocities and found to be strongly velocity dependent at low velocities. A simple relation was developed to correct for the variation of yaw response at low velocities. The method using the yaw correction is compared with the single-velocity yaw calibration method. The correction to the yaw response considerably improves accuracy at low velocities. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | A Simple and Accurate Method of Calibrating X-Probes | |
type | Journal Paper | |
journal volume | 115 | |
journal issue | 1 | |
journal title | Journal of Fluids Engineering | |
identifier doi | 10.1115/1.2910098 | |
journal fristpage | 148 | |
journal lastpage | 152 | |
identifier eissn | 1528-901X | |
keywords | Probes | |
keywords | Yaw | |
keywords | Flow (Dynamics) AND Calibration | |
tree | Journal of Fluids Engineering:;1993:;volume( 115 ):;issue: 001 | |
contenttype | Fulltext | |