YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    The Zero-Stress State of Rat Veins and Vena Cava

    Source: Journal of Biomechanical Engineering:;1991:;volume( 113 ):;issue: 001::page 36
    Author:
    J. P. Xie
    ,
    S. Q. Liu
    ,
    R. F. Yang
    ,
    Y. C. Fung
    DOI: 10.1115/1.2894083
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The zero-stress state of a vein is, like that of an artery, not a closed cylindrical tube, but is a series of segments whose cross-sections are open sectors. An opening angle of each sector is defined as the angle subtended between two radii joining the midpoint of the inner wall to the tips of the inner wall. Data on the opening angles (mean ± standard deviation) of the veins and vena cava of the rat are presented. For the superior vena cava and subclavian, jugular, facial, renal, common iliac, saphenous, and plantar veins, the opening angle varies in the range of 25 to 75 deg. The inferior vena cava (below the heart), however, has noncircular, nonaxisymmetric cross-sections, a curved axis, and a rapid longitudinal variation of its “diameter;” its zero-stress state is not circular sectors; but the opening angle is still a useful characterization. The mean opening angle of the interior vena cava varies in the range of 40 to 150 deg in the thoracic portion, and 75 to 130 deg in the abdominal portion, with the larger values occurring about the middle of each portion. There are considerable length, diameter reductions, and wall thickening of the vena cava from the homeostatic state to the no-load state in vitro. Physically, the zero-stress state is the basis of the stress analysis of blood vessels. The change of opening angle is a convenient parameter to characterize any nonuniform remodeling of the vessel wall due to changes in physical stress or chemical environment. Change of zerostress state influences the compliance and collapsibility of the viens, their pressure-volume and pressure-flow relationships, the waterfall phenomenon, and the tone in the vascular smooth muscles if the homeostatic stress is changed.
    keyword(s): Stress , Cross section (Physics) , Pressure , Flow (Dynamics) , Joining , Stress analysis (Engineering) , Blood vessels , Kidney , Muscle AND Vessels ,
    • Download: (1.384Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Zero-Stress State of Rat Veins and Vena Cava

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/108198
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorJ. P. Xie
    contributor authorS. Q. Liu
    contributor authorR. F. Yang
    contributor authorY. C. Fung
    date accessioned2017-05-08T23:34:55Z
    date available2017-05-08T23:34:55Z
    date copyrightFebruary, 1991
    date issued1991
    identifier issn0148-0731
    identifier otherJBENDY-25868#36_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/108198
    description abstractThe zero-stress state of a vein is, like that of an artery, not a closed cylindrical tube, but is a series of segments whose cross-sections are open sectors. An opening angle of each sector is defined as the angle subtended between two radii joining the midpoint of the inner wall to the tips of the inner wall. Data on the opening angles (mean ± standard deviation) of the veins and vena cava of the rat are presented. For the superior vena cava and subclavian, jugular, facial, renal, common iliac, saphenous, and plantar veins, the opening angle varies in the range of 25 to 75 deg. The inferior vena cava (below the heart), however, has noncircular, nonaxisymmetric cross-sections, a curved axis, and a rapid longitudinal variation of its “diameter;” its zero-stress state is not circular sectors; but the opening angle is still a useful characterization. The mean opening angle of the interior vena cava varies in the range of 40 to 150 deg in the thoracic portion, and 75 to 130 deg in the abdominal portion, with the larger values occurring about the middle of each portion. There are considerable length, diameter reductions, and wall thickening of the vena cava from the homeostatic state to the no-load state in vitro. Physically, the zero-stress state is the basis of the stress analysis of blood vessels. The change of opening angle is a convenient parameter to characterize any nonuniform remodeling of the vessel wall due to changes in physical stress or chemical environment. Change of zerostress state influences the compliance and collapsibility of the viens, their pressure-volume and pressure-flow relationships, the waterfall phenomenon, and the tone in the vascular smooth muscles if the homeostatic stress is changed.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Zero-Stress State of Rat Veins and Vena Cava
    typeJournal Paper
    journal volume113
    journal issue1
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.2894083
    journal fristpage36
    journal lastpage41
    identifier eissn1528-8951
    keywordsStress
    keywordsCross section (Physics)
    keywordsPressure
    keywordsFlow (Dynamics)
    keywordsJoining
    keywordsStress analysis (Engineering)
    keywordsBlood vessels
    keywordsKidney
    keywordsMuscle AND Vessels
    treeJournal of Biomechanical Engineering:;1991:;volume( 113 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian