YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Turbomachinery
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Turbomachinery
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Local Heat Transfer in Internally Cooled Turbine Airfoil Leading Edge Regions: Part II—Impingement Cooling With Film Coolant Extraction

    Source: Journal of Turbomachinery:;1990:;volume( 112 ):;issue: 003::page 459
    Author:
    D. E. Metzger
    ,
    R. S. Bunker
    DOI: 10.1115/1.2927681
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: An experimental study has been designed and performed to measure very localized internal heat transfer characteristics in large-scale models of turbine blade impingement-cooled leading edge regions that allow extraction, or bleed-off, of a portion of the internal cooling flow to provide leading edge film cooling along the blade external surface. The internal impingement air is provided by a single line of equally spaced multiple jets, aimed at the leading edge apex and generally exiting, minus the bleed-off flow, in the opposite or chordwise direction. The film coolant flow extraction takes place through two lines of holes, one each on the blade suction side and the blade pressure side, both fairly close to the airfoil leading edge. Detailed two-dimensional local surface Nusselt number distributions have been obtained through the use of aerodynamically steady but thermally transient tests employing temperature-indicating coatings. The thin coatings are sprayed directly on the test surfaces, and are observed during a test transient with automated computer vision and data acquisition systems. A wide range of parameter combinations of interest in cooled airfoil practice is covered in the test matrix, including combinations of variations in jet Reynolds number, airfoil leading edge sharpness, jet pitch-to-diameter ratio, and jet nozzle-to-apex travel distance. Measured local Nusselt numbers at each chordwise location back from the stagnation line have been used to calculate both the spanwise-average Nusselt numbers and spanwise Nusselt number gradients as functions of chordwise position. The results without film coolant extraction, presented in the Part I companion paper, are used as a basis of comparison to determine the additional effects of the film cooling bleed. Results indicate that heat transfer is primarily dependent on jet Reynolds number with smaller influences from the flow extraction rate. The results also suggest that changes in the spanwise alignment of the impingement nozzles relative to the position of the film cooling holes can cause significant variations in leading edge metal temperatures.
    keyword(s): Heat transfer , Coolants , Impingement cooling , Turbines , Airfoils , Cooling , Flow (Dynamics) , Blades , Nozzles , Temperature , Coatings , Reynolds number , Pressure , Suction , Metals , Turbine blades , Jets , Functions , Gradients , Travel , Data acquisition systems AND Computers ,
    • Download: (802.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Local Heat Transfer in Internally Cooled Turbine Airfoil Leading Edge Regions: Part II—Impingement Cooling With Film Coolant Extraction

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/107736
    Collections
    • Journal of Turbomachinery

    Show full item record

    contributor authorD. E. Metzger
    contributor authorR. S. Bunker
    date accessioned2017-05-08T23:34:06Z
    date available2017-05-08T23:34:06Z
    date copyrightJuly, 1990
    date issued1990
    identifier issn0889-504X
    identifier otherJOTUEI-28604#459_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/107736
    description abstractAn experimental study has been designed and performed to measure very localized internal heat transfer characteristics in large-scale models of turbine blade impingement-cooled leading edge regions that allow extraction, or bleed-off, of a portion of the internal cooling flow to provide leading edge film cooling along the blade external surface. The internal impingement air is provided by a single line of equally spaced multiple jets, aimed at the leading edge apex and generally exiting, minus the bleed-off flow, in the opposite or chordwise direction. The film coolant flow extraction takes place through two lines of holes, one each on the blade suction side and the blade pressure side, both fairly close to the airfoil leading edge. Detailed two-dimensional local surface Nusselt number distributions have been obtained through the use of aerodynamically steady but thermally transient tests employing temperature-indicating coatings. The thin coatings are sprayed directly on the test surfaces, and are observed during a test transient with automated computer vision and data acquisition systems. A wide range of parameter combinations of interest in cooled airfoil practice is covered in the test matrix, including combinations of variations in jet Reynolds number, airfoil leading edge sharpness, jet pitch-to-diameter ratio, and jet nozzle-to-apex travel distance. Measured local Nusselt numbers at each chordwise location back from the stagnation line have been used to calculate both the spanwise-average Nusselt numbers and spanwise Nusselt number gradients as functions of chordwise position. The results without film coolant extraction, presented in the Part I companion paper, are used as a basis of comparison to determine the additional effects of the film cooling bleed. Results indicate that heat transfer is primarily dependent on jet Reynolds number with smaller influences from the flow extraction rate. The results also suggest that changes in the spanwise alignment of the impingement nozzles relative to the position of the film cooling holes can cause significant variations in leading edge metal temperatures.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleLocal Heat Transfer in Internally Cooled Turbine Airfoil Leading Edge Regions: Part II—Impingement Cooling With Film Coolant Extraction
    typeJournal Paper
    journal volume112
    journal issue3
    journal titleJournal of Turbomachinery
    identifier doi10.1115/1.2927681
    journal fristpage459
    journal lastpage466
    identifier eissn1528-8900
    keywordsHeat transfer
    keywordsCoolants
    keywordsImpingement cooling
    keywordsTurbines
    keywordsAirfoils
    keywordsCooling
    keywordsFlow (Dynamics)
    keywordsBlades
    keywordsNozzles
    keywordsTemperature
    keywordsCoatings
    keywordsReynolds number
    keywordsPressure
    keywordsSuction
    keywordsMetals
    keywordsTurbine blades
    keywordsJets
    keywordsFunctions
    keywordsGradients
    keywordsTravel
    keywordsData acquisition systems AND Computers
    treeJournal of Turbomachinery:;1990:;volume( 112 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian