    Persistence of Asymmetry in Nonaxisymmetric Entry Flow in a Circular Cylindrical Tube and Its Relevance to Arterial Pulse Wave Diagnosis

    Source: Journal of Biomechanical Engineering:;1989:;volume( 111 ):;issue: 001::page 37
    Author:
    H. Xue
    ,
    Y. C. Fung
    DOI: 10.1115/1.3168337
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In an experiment motivated by the study of arterial blood flow along the lines suggested by the traditional Chinese medicine, the flow in a pipe whose lumen was blocked by a semi-circular plug two tube-diameters long was visualized by suspended particles, recorded by cinematography, and analyzed digitally. The Reynolds number was in the range of 100 to 450 based on the pipe diameter, similar to that of blood flow in the radial artery in the arms of man. The blockage was found to have a profound effect on the velocity profile of the flow in the wake, but it had little influence on the symmetry of the velocity profile upstream of the block, except in its immediate neighborhood. When the end conditions far away from the block were steady, the flow in the wake was steady. The asymmetry of the flow in the wake can be judged by the deviation of the location of the maximum axial velocity from the center line of the pipe as seen in the plane of symmetry of the blockage. Our results show that the deviation can be described as the sum of two components. The first is a strong one which decays exponentially in an entry length which is about twice as long as the classical Boussinesq entry length of axisymmetric flow. The second is a weaker component which is wavy spatially and persists far downstream (many times the entry length). The separated flow and vortex system behind the blockage are sensitive to the flow rate. The relevance of these findings to the arterial pulse wave diagnosis methods used in the traditional Chinese medicine is discussed. We show that the human arteries are shorter than the entry length, hence nonaxisymmetric disturbances can be propagated throughout the circulation system. We propose that the propagation of the persistent, small, wavy asymmetric wave is relevant to the “localization” of the spheres of influence of internal and external organs in a two-inch region of the radial artery. We propose further that the method of pressing hard on the artery to “feel” the pulse is to amplify the signal by creating a wake that is very sensitive to velocity of flow.
    keyword(s): Flow (Dynamics) , Waves , Patient diagnosis , Wakes , Pipes , Blood flow , Signals , Vortices , Particulate matter , Reynolds number AND Pressing (Garments) ,
    • Download: (1.333Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Persistence of Asymmetry in Nonaxisymmetric Entry Flow in a Circular Cylindrical Tube and Its Relevance to Arterial Pulse Wave Diagnosis

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/105095
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorH. Xue
    contributor authorY. C. Fung
    date accessioned2017-05-08T23:29:27Z
    date available2017-05-08T23:29:27Z
    date copyrightFebruary, 1989
    date issued1989
    identifier issn0148-0731
    identifier otherJBENDY-25845#37_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/105095
    description abstractIn an experiment motivated by the study of arterial blood flow along the lines suggested by the traditional Chinese medicine, the flow in a pipe whose lumen was blocked by a semi-circular plug two tube-diameters long was visualized by suspended particles, recorded by cinematography, and analyzed digitally. The Reynolds number was in the range of 100 to 450 based on the pipe diameter, similar to that of blood flow in the radial artery in the arms of man. The blockage was found to have a profound effect on the velocity profile of the flow in the wake, but it had little influence on the symmetry of the velocity profile upstream of the block, except in its immediate neighborhood. When the end conditions far away from the block were steady, the flow in the wake was steady. The asymmetry of the flow in the wake can be judged by the deviation of the location of the maximum axial velocity from the center line of the pipe as seen in the plane of symmetry of the blockage. Our results show that the deviation can be described as the sum of two components. The first is a strong one which decays exponentially in an entry length which is about twice as long as the classical Boussinesq entry length of axisymmetric flow. The second is a weaker component which is wavy spatially and persists far downstream (many times the entry length). The separated flow and vortex system behind the blockage are sensitive to the flow rate. The relevance of these findings to the arterial pulse wave diagnosis methods used in the traditional Chinese medicine is discussed. We show that the human arteries are shorter than the entry length, hence nonaxisymmetric disturbances can be propagated throughout the circulation system. We propose that the propagation of the persistent, small, wavy asymmetric wave is relevant to the “localization” of the spheres of influence of internal and external organs in a two-inch region of the radial artery. We propose further that the method of pressing hard on the artery to “feel” the pulse is to amplify the signal by creating a wake that is very sensitive to velocity of flow.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePersistence of Asymmetry in Nonaxisymmetric Entry Flow in a Circular Cylindrical Tube and Its Relevance to Arterial Pulse Wave Diagnosis
    typeJournal Paper
    journal volume111
    journal issue1
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.3168337
    journal fristpage37
    journal lastpage41
    identifier eissn1528-8951
    keywordsFlow (Dynamics)
    keywordsWaves
    keywordsPatient diagnosis
    keywordsWakes
    keywordsPipes
    keywordsBlood flow
    keywordsSignals
    keywordsVortices
    keywordsParticulate matter
    keywordsReynolds number AND Pressing (Garments)
    treeJournal of Biomechanical Engineering:;1989:;volume( 111 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian