    Turbulence Measurements With Symmetrically Bent V-Shaped Hot-Wires. Part 1: Principles of Operation

    Source: Journal of Fluids Engineering:;1988:;volume( 110 ):;issue: 003::page 264
    Author:
    M. Hishida
    ,
    Y. Nagano
    DOI: 10.1115/1.3243543
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A new anemometry technique has been developed for turbulence measurements near the wall, where the conventional X-wire method is subject to large errors due to aerodynamic disturbances caused by the tips of wire supports. The technique proposed in this study is founded on the principle of convective heat transfer from a symmetrically bent V-shaped hot-wire, which can be supported just like a cantilever. The present paper describes the details of effective cooling velocities of a V-shaped hot-wire, together with the related comments on its aeroelastic deformation and vibration.
    keyword(s): Measurement , Turbulence , Wire , Convection , Vibration , Cantilevers , Errors , Deformation AND Cooling ,
    • Download: (859.9Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Turbulence Measurements With Symmetrically Bent V-Shaped Hot-Wires. Part 1: Principles of Operation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/104036
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorM. Hishida
    contributor authorY. Nagano
    date accessioned2017-05-08T23:27:25Z
    date available2017-05-08T23:27:25Z
    date copyrightSeptember, 1988
    date issued1988
    identifier issn0098-2202
    identifier otherJFEGA4-27036#264_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/104036
    description abstractA new anemometry technique has been developed for turbulence measurements near the wall, where the conventional X-wire method is subject to large errors due to aerodynamic disturbances caused by the tips of wire supports. The technique proposed in this study is founded on the principle of convective heat transfer from a symmetrically bent V-shaped hot-wire, which can be supported just like a cantilever. The present paper describes the details of effective cooling velocities of a V-shaped hot-wire, together with the related comments on its aeroelastic deformation and vibration.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleTurbulence Measurements With Symmetrically Bent V-Shaped Hot-Wires. Part 1: Principles of Operation
    typeJournal Paper
    journal volume110
    journal issue3
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3243543
    journal fristpage264
    journal lastpage269
    identifier eissn1528-901X
    keywordsMeasurement
    keywordsTurbulence
    keywordsWire
    keywordsConvection
    keywordsVibration
    keywordsCantilevers
    keywordsErrors
    keywordsDeformation AND Cooling
    treeJournal of Fluids Engineering:;1988:;volume( 110 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian