    Archive

    A Design Procedure for Evaluating the Tube Axial Load due to Thermal Effects in Multi-Pass Fixed Tubesheet Exchangers

    Source: Journal of Pressure Vessel Technology:;1987:;volume( 109 ):;issue: 001::page 27
    Author:
    K. P. Singh
    ,
    A. I. Soler
    DOI: 10.1115/1.3264852
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The unequal length change of the tubes in various tube passes of a multi-tube pass fixed or floating head tubular exchanger produces axial tube loads which may be substantial in some operating units. This paper provides a rational analysis method, heretofore unavailable to the design community, to quantify the effect of multi-pass thermal expansion on the tube axial load. A numerical example is used to illustrate the solution procedure.
    keyword(s): Stress , Temperature effects , Design AND Thermal expansion ,
    • Download: (520.1Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Design Procedure for Evaluating the Tube Axial Load due to Thermal Effects in Multi-Pass Fixed Tubesheet Exchangers

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/102943
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorK. P. Singh
    contributor authorA. I. Soler
    date accessioned2017-05-08T23:25:34Z
    date available2017-05-08T23:25:34Z
    date copyrightFebruary, 1987
    date issued1987
    identifier issn0094-9930
    identifier otherJPVTAS-28281#27_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/102943
    description abstractThe unequal length change of the tubes in various tube passes of a multi-tube pass fixed or floating head tubular exchanger produces axial tube loads which may be substantial in some operating units. This paper provides a rational analysis method, heretofore unavailable to the design community, to quantify the effect of multi-pass thermal expansion on the tube axial load. A numerical example is used to illustrate the solution procedure.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Design Procedure for Evaluating the Tube Axial Load due to Thermal Effects in Multi-Pass Fixed Tubesheet Exchangers
    typeJournal Paper
    journal volume109
    journal issue1
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.3264852
    journal fristpage27
    journal lastpage32
    identifier eissn1528-8978
    keywordsStress
    keywordsTemperature effects
    keywordsDesign AND Thermal expansion
    treeJournal of Pressure Vessel Technology:;1987:;volume( 109 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian