description abstractHeat transfer factors and thermal efficiency are calculated for a heat pipe absorber array connected to a common manifold. Arrays with less than ten heat pipes are shown to have significantly less efficiency than a conventional flow-through collector. Efficiency is also sensitive to the heat transfer rate per unit temperature difference from the heat pipe fluid to the manifold fluid divided by that from the heat pipe surface to the ambient, with maximum efficiency occurring for ratios greater than 100.
publisherThe American Society of Mechanical Engineers (ASME)
titleAnalysis of Heat Transfer Factors for a Heat Pipe Absorber Array Connected to a Common Manifold
typeJournal Paper
journal volume108
journal issue1
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.3268037
journal fristpage11
journal lastpage16
identifier eissn1528-8986
keywordsHeat transfer
keywordsHeat pipes
keywordsManifolds
keywordsFluids
keywordsFlow (Dynamics) AND Temperature
treeJournal of Solar Energy Engineering:;1986:;volume( 108 ):;issue: 001