description abstractVolumetric heat transfer coefficients for direct-contact heat exchange between air and molten nitrate salt have been measured as a function of air and salt flow rates at 350° C salt inlet temperature. Using these heat transfer data for a packed column-type heat exchanger, an economic analysis was used to compare direct-contact heat exchange with conventional finned-tube heat exchangers. High volumetric rates of heat transfer (2000–3000 W/m3 °C) and flexibility in choice of materials of construction allow one to realize significant economic benefits by using direct-contact heat exchange in this application.
publisherThe American Society of Mechanical Engineers (ASME)
titleAir Molten Salt Direct-Contact Heat Exchange
typeJournal Paper
journal volume107
journal issue3
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.3267680
journal fristpage208
journal lastpage214
identifier eissn1528-8986
keywordsHeat
keywordsHeat transfer
keywordsHeat exchangers
keywordsEconomic analysis
keywordsHeat transfer coefficients
keywordsConstruction
keywordsTemperature
keywordsFlow (Dynamics) AND Plasticity
treeJournal of Solar Energy Engineering:;1985:;volume( 107 ):;issue: 003