Simulation-Based Assessment of Performance Indicator for Data Center Cooling Optimization
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Data center power consumption has grown substantially in the past 20 years. According to the United States Data Center Energy Usage Report, the data center consumption in 2014 was estimated at 70 billion kWh, which accounted ...
Experimental and Numerical Analysis of Data Center Pressure and Flow Fields Induced by Backward and Forward CRAH Technology
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: An increasingly common power saving practice in data center thermal management is to swap out air cooling unit blower fans with electronically commutated plug fans, Although, both are centrifugal blowers. The blade design ...
A Novel Design of Rack Mount Server Thermal Simulator: Design, Assembly, and Experimental Verification
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The practice of commissioning data centers (DCs) is necessary to confirm the compliance of the cooling system to the information technology equipment (ITE) load (design capacity). In a typical DC, there are different types ...
Comprehensive Experimental and Computational Analysis of a Fully Contained Hybrid Server Cabinet
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The rapid growth in the number of data centers combined with the high-density heat dissipation of computer and telecommunications equipment has made energy efficient thermal management of data centers a key research area. ...
Impact of Server Thermal Design on the Cooling Efficiency: Chassis Design
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: There are various designs for segregating hot and cold air in data centers such as cold aisle containment (CAC), hot aisle containment (HAC), and chimney exhaust rack. These containment systems have different characteristics ...
Impact of Tile Design on the Thermal Performance of Open and Enclosed Aisles
Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: In raised floor data centers, tiles with high open area ratio or complex understructure are used to fulfill the demand of today's high-density computing. Using more open tiles reduces the pressure drop across the raised ...
Impact of Server Thermal Design on the Cooling Efficiency: Chassis Design
Publisher: American Society of Mechanical Engineers (ASME)
Abstract: There are various designs for segregating hot and cold air in data centers such as cold aisle containment (CAC), hot aisle containment (HAC), and chimney exhaust rack. These containment systems have different characteristics ...