YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    Search 
    •   YE&T Library
    • Search
    •   YE&T Library
    • Search
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Search

    Show Advanced FiltersHide Advanced Filters

    Filters

    Use filters to refine the search results.

    Now showing items 1-7 of 7

    • Relevance
    • Title Asc
    • Title Desc
    • Year Asc
    • Year Desc
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100
  • Export
    • CSV
    • RIS
    • Sort Options:
    • Relevance
    • Title Asc
    • Title Desc
    • Issue Date Asc
    • Issue Date Desc
    • Results Per Page:
    • 5
    • 10
    • 20
    • 40
    • 60
    • 80
    • 100

    The Accelerated Transcatheter Heart Valve Testing Environment: Loading, Motion, and Fluid Dynamics 

    Source: Journal of Biomechanical Engineering:;2022:;volume( 145 ):;issue: 003:;page 31005-1
    Author(s): Ponnaluri, Sailahari V.; Sacks, Michael S.; Manning, Keefe B.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Transcatheter aortic valve replacements (TAVRs) are an increasingly common treatment for aortic valve disease due to their minimally invasive delivery. As TAVR designs require thinner leaflets to facilitate catheter-based ...
    Request PDF

    Fluid Dynamic Study of the Penn State Pediatric Total Artificial Heart 

    Source: Journal of Biomechanical Engineering:;2024:;volume( 146 ):;issue: 010:;page 101007-1
    Author(s): Kubicki, Cody; Raich, Emma; Selinsky, Peter; Ponnaluri, Sailahari; Weiss, William J.; Manning, Keefe B.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Penn State University is developing a pediatric total artificial heart (TAH) as a bridge-to-transplant device that supports infants and small children with single ventricle anomalies or biventricular heart failure to address ...
    Request PDF

    Characterizing the HeartMate II Left Ventricular Assist Device Outflow Using Particle Image Velocimetry 

    Source: Journal of Biomechanical Engineering:;2018:;volume( 140 ):;issue: 007:;page 71008
    Author(s): Rowlands, Grant W.; Good, Bryan C.; Deutsch, Steven; Manning, Keefe B.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Ventricular assist devices (VADs) are implanted in patients with a diseased ventricle to maintain peripheral perfusion as a bridge-to-transplant or as destination therapy. However, some patients with continuous flow VADs ...
    Request PDF

    Experimental Hemodynamics Within the Penn State Fontan Circulatory Assist Device 

    Source: Journal of Biomechanical Engineering:;2022:;volume( 144 ):;issue: 007:;page 71004-1
    Author(s): Ponnaluri, Sailahari V.; Christensen, Emma J.; Good, Bryan C.; Kubicki, Cody J.; Deutsch, Steven; Cysyk, Joshua P.; Weiss, William J.; Manning, Keefe B.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: For children born with a single functional ventricle, the Fontan operation bypasses the right ventricle by forming a four-way total cavopulmonary connection and adapts the existing ventricle for the systemic circulation. ...
    Request PDF

    In Vitro Quantification of Time Dependent Thrombus Size Using Magnetic Resonance Imaging and Computational Simulations of Thrombus Surface Shear Stresses 

    Source: Journal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 007:;page 71012
    Author(s): Taylor, Joshua O.; Witmer, Kory P.; Neuberger, Thomas; Craven, Brent A.; Meyer, Richard S.; Deutsch, Steven; Manning, Keefe B.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Thrombosis and thromboembolization remain large obstacles in the design of cardiovascular devices. In this study, the temporal behavior of thrombus size within a backwardfacing step (BFS) model is investigated, as this ...
    Request PDF

    Toward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid–Structure Interaction-Based Strategy to the Penn State 12 cc Device 

    Source: Journal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 008:;page 81008
    Author(s): Caimi, Alessandro; Sturla, Francesco; Good, Bryan; Vidotto, Marco; De Ponti, Rachele; Piatti, Filippo; Manning, Keefe B.; Redaelli, Alberto
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The pediatric use of pneumatic ventricular assist devices (VADs) as a bridge to heart transplant still suffers for short-term major complications such as bleeding and thromboembolism. Although numerical techniques are ...
    Request PDF

    A Computational Method for Predicting Inferior Vena Cava Filter Performance on a Patient Specific Basis 

    Source: Journal of Biomechanical Engineering:;2014:;volume( 136 ):;issue: 008:;page 81003
    Author(s): Aycock, Kenneth I.; Campbell, Robert L.; Manning, Keefe B.; Sastry, Shankar P.; Shontz, Suzanne M.; Lynch, Frank C.; Craven, Brent A.
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A computational methodology for simulating virtual inferior vena cava (IVC) filter placement and IVC hemodynamics was developed and demonstrated in two patientspecific IVC geometries: a leftsided IVC and an IVC with a ...
    Request PDF
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     

    Author

    ... View More

    Publisher

    Year

    Type

    Content Type

    Publication Title

    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian