Effect of Tubing on Measurements of Small Transient Pressure Signals in LiquidsSource: Journal of Dynamic Systems, Measurement, and Control:;1983:;volume( 105 ):;issue: 004::page 262Author:M. M. Farid
DOI: 10.1115/1.3140668Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: It is often necessary to connect the pressure transducer used for measurements of static and dynamic pressure signals to the pressure source by means of a connecting tube. The effects of the tube length and diameter on a relatively small step pressure signal in a liquid system have been studied experimentally and analyzed theoretically. Theoretical equations to predict the natural frequency and the damping coefficient of the system are obtained so that the proper length and diameter of tubing can be selected for minimum distortion of the step input signal. Agreement between theoretical predictions and experimental measurements was found to be reasonably good.
|
Show full item record
| contributor author | M. M. Farid | |
| date accessioned | 2017-05-08T23:15:05Z | |
| date available | 2017-05-08T23:15:05Z | |
| date copyright | December, 1983 | |
| date issued | 1983 | |
| identifier issn | 0022-0434 | |
| identifier other | JDSMAA-26079#262_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/96839 | |
| description abstract | It is often necessary to connect the pressure transducer used for measurements of static and dynamic pressure signals to the pressure source by means of a connecting tube. The effects of the tube length and diameter on a relatively small step pressure signal in a liquid system have been studied experimentally and analyzed theoretically. Theoretical equations to predict the natural frequency and the damping coefficient of the system are obtained so that the proper length and diameter of tubing can be selected for minimum distortion of the step input signal. Agreement between theoretical predictions and experimental measurements was found to be reasonably good. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Effect of Tubing on Measurements of Small Transient Pressure Signals in Liquids | |
| type | Journal Paper | |
| journal volume | 105 | |
| journal issue | 4 | |
| journal title | Journal of Dynamic Systems, Measurement, and Control | |
| identifier doi | 10.1115/1.3140668 | |
| journal fristpage | 262 | |
| journal lastpage | 264 | |
| identifier eissn | 1528-9028 | |
| tree | Journal of Dynamic Systems, Measurement, and Control:;1983:;volume( 105 ):;issue: 004 | |
| contenttype | Fulltext |