    Design and Analysis of Multispan Straight Tubes for Elevated Temperature Heat Exchanger Service

    Source: Journal of Pressure Vessel Technology:;1980:;volume( 102 ):;issue: 004::page 363
    Author:
    R. V. Roché
    ,
    D. H. Pai
    DOI: 10.1115/1.3263346
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The behavior of multispan SS304 tubes intended for elevated temperature heat exchanger service is investigated. Particular attention was paid to the ASME Code Case 1592 criteria on buckling. It was found that for the loadings and geometric parameters examined, the behavior of the multispan tubes can be characterized as strain controlled. Code Case 1592 rules were found to be conservative for all the cases investigated. A suggestion to refine the Code Case rules is also given.
    keyword(s): Temperature , Design , Heat exchangers , Buckling AND ASME Standards ,
    • Download: (725.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Design and Analysis of Multispan Straight Tubes for Elevated Temperature Heat Exchanger Service

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/93762
    Collections
    • Journal of Pressure Vessel Technology

    Show full item record

    contributor authorR. V. Roché
    contributor authorD. H. Pai
    date accessioned2017-05-08T23:09:38Z
    date available2017-05-08T23:09:38Z
    date copyrightNovember, 1980
    date issued1980
    identifier issn0094-9930
    identifier otherJPVTAS-28192#363_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/93762
    description abstractThe behavior of multispan SS304 tubes intended for elevated temperature heat exchanger service is investigated. Particular attention was paid to the ASME Code Case 1592 criteria on buckling. It was found that for the loadings and geometric parameters examined, the behavior of the multispan tubes can be characterized as strain controlled. Code Case 1592 rules were found to be conservative for all the cases investigated. A suggestion to refine the Code Case rules is also given.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign and Analysis of Multispan Straight Tubes for Elevated Temperature Heat Exchanger Service
    typeJournal Paper
    journal volume102
    journal issue4
    journal titleJournal of Pressure Vessel Technology
    identifier doi10.1115/1.3263346
    journal fristpage363
    journal lastpage370
    identifier eissn1528-8978
    keywordsTemperature
    keywordsDesign
    keywordsHeat exchangers
    keywordsBuckling AND ASME Standards
    treeJournal of Pressure Vessel Technology:;1980:;volume( 102 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian