Factors Affecting the Design of Turbine-Condenser ConnectionsSource: Journal of Engineering for Gas Turbines and Power:;1977:;volume( 099 ):;issue: 003::page 429Author:J. E. Fowler
DOI: 10.1115/1.3446525Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Those features of the design of the interconnection between a large steam turbine and the condenser which may affect the plant heat rate or turbine reliability are reviewed. The performance losses resulting from geometric mismatching of turbine hood and condenser and those due to obstructions and extraneous flow injections are assessed. The effects on turbine reliability of differing arrangements for injecting extraneous steam or water flows are pointed out with examples. Suggestions are given for the practices to be followed in this area of plant design.
keyword(s): Design , Turbines , Condensers (steam plant) , Flow (Dynamics) , Reliability , Heat , Industrial plants , Steam , Steam turbines , Water AND Plant design ,
|
Show full item record
| contributor author | J. E. Fowler | |
| date accessioned | 2017-05-08T23:02:46Z | |
| date available | 2017-05-08T23:02:46Z | |
| date copyright | July, 1977 | |
| date issued | 1977 | |
| identifier issn | 1528-8919 | |
| identifier other | JETPEZ-26734#429_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/89798 | |
| description abstract | Those features of the design of the interconnection between a large steam turbine and the condenser which may affect the plant heat rate or turbine reliability are reviewed. The performance losses resulting from geometric mismatching of turbine hood and condenser and those due to obstructions and extraneous flow injections are assessed. The effects on turbine reliability of differing arrangements for injecting extraneous steam or water flows are pointed out with examples. Suggestions are given for the practices to be followed in this area of plant design. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Factors Affecting the Design of Turbine-Condenser Connections | |
| type | Journal Paper | |
| journal volume | 99 | |
| journal issue | 3 | |
| journal title | Journal of Engineering for Gas Turbines and Power | |
| identifier doi | 10.1115/1.3446525 | |
| journal fristpage | 429 | |
| journal lastpage | 436 | |
| identifier eissn | 0742-4795 | |
| keywords | Design | |
| keywords | Turbines | |
| keywords | Condensers (steam plant) | |
| keywords | Flow (Dynamics) | |
| keywords | Reliability | |
| keywords | Heat | |
| keywords | Industrial plants | |
| keywords | Steam | |
| keywords | Steam turbines | |
| keywords | Water AND Plant design | |
| tree | Journal of Engineering for Gas Turbines and Power:;1977:;volume( 099 ):;issue: 003 | |
| contenttype | Fulltext |