Show simple item record

contributor authorJ. E. Fowler
date accessioned2017-05-08T23:02:46Z
date available2017-05-08T23:02:46Z
date copyrightJuly, 1977
date issued1977
identifier issn1528-8919
identifier otherJETPEZ-26734#429_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/89798
description abstractThose features of the design of the interconnection between a large steam turbine and the condenser which may affect the plant heat rate or turbine reliability are reviewed. The performance losses resulting from geometric mismatching of turbine hood and condenser and those due to obstructions and extraneous flow injections are assessed. The effects on turbine reliability of differing arrangements for injecting extraneous steam or water flows are pointed out with examples. Suggestions are given for the practices to be followed in this area of plant design.
publisherThe American Society of Mechanical Engineers (ASME)
titleFactors Affecting the Design of Turbine-Condenser Connections
typeJournal Paper
journal volume99
journal issue3
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.3446525
journal fristpage429
journal lastpage436
identifier eissn0742-4795
keywordsDesign
keywordsTurbines
keywordsCondensers (steam plant)
keywordsFlow (Dynamics)
keywordsReliability
keywordsHeat
keywordsIndustrial plants
keywordsSteam
keywordsSteam turbines
keywordsWater AND Plant design
treeJournal of Engineering for Gas Turbines and Power:;1977:;volume( 099 ):;issue: 003