    The Paradox of the Vena Contracta

    Source: Journal of Fluids Engineering:;1975:;volume( 097 ):;issue: 003::page 366
    Author:
    M. P. Wilson
    ,
    R. G. Teyssandier
    DOI: 10.1115/1.3447316
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The preponderance of evidence, both theoretical and experimental, appears to show that the vena contracta does not occur at the same location as the minimum pressure point in the Reynolds number range greater than 10,000. Fortunately, however, this result has little effect on the measurement engineer in the field. All of the coefficients for vena contracta taps remain valid except that they should probably be referred to as “minimum pressure point taps” unless someone can provide a simpler description.
    keyword(s): Pressure , Engineers AND Reynolds number ,
    • Download: (467.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      The Paradox of the Vena Contracta

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/87633
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorM. P. Wilson
    contributor authorR. G. Teyssandier
    date accessioned2017-05-08T22:58:53Z
    date available2017-05-08T22:58:53Z
    date copyrightSeptember, 1975
    date issued1975
    identifier issn0098-2202
    identifier otherJFEGA4-26873#366_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/87633
    description abstractThe preponderance of evidence, both theoretical and experimental, appears to show that the vena contracta does not occur at the same location as the minimum pressure point in the Reynolds number range greater than 10,000. Fortunately, however, this result has little effect on the measurement engineer in the field. All of the coefficients for vena contracta taps remain valid except that they should probably be referred to as “minimum pressure point taps” unless someone can provide a simpler description.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Paradox of the Vena Contracta
    typeJournal Paper
    journal volume97
    journal issue3
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3447316
    journal fristpage366
    journal lastpage371
    identifier eissn1528-901X
    keywordsPressure
    keywordsEngineers AND Reynolds number
    treeJournal of Fluids Engineering:;1975:;volume( 097 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian