description abstractThe preponderance of evidence, both theoretical and experimental, appears to show that the vena contracta does not occur at the same location as the minimum pressure point in the Reynolds number range greater than 10,000. Fortunately, however, this result has little effect on the measurement engineer in the field. All of the coefficients for vena contracta taps remain valid except that they should probably be referred to as “minimum pressure point taps” unless someone can provide a simpler description.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Paradox of the Vena Contracta
typeJournal Paper
journal volume97
journal issue3
journal titleJournal of Fluids Engineering
identifier doi10.1115/1.3447316
journal fristpage366
journal lastpage371
identifier eissn1528-901X
keywordsPressure
keywordsEngineers AND Reynolds number
treeJournal of Fluids Engineering:;1975:;volume( 097 ):;issue: 003