    Mansion House London: Risk Assessment and Protection

    Source: Journal of Construction Engineering and Management:;1995:;Volume ( 121 ):;issue: 003
    Author:
    A. J. Powderham
    ,
    G. J. Tamaro
    DOI: 10.1061/(ASCE)0733-9364(1995)121:3(266)
    Publisher: American Society of Civil Engineers
    Abstract: Settlements occurring during the first phase of tunneling for the extension of the Docklands Light Railway in London caused concern for damage to the Mansion House during subsequent phases of the work. The building is a landmark structure and no further damage could be accepted. Tunneling was halted until a satisfactory protection program was in place. Various means of protecting the structure were investigated, ranging from full structural underpinning to a least-risk methodology based on the observational method. This paper describes the background to the development and implementation of the observational method to successfully protect the building and complete construction. This required appropriate contingency measures to be identified and planned in advance. Of the contingencies involving preventive or strengthening works, a system of structural ties through the building was selected as most appropriate, least risky, and most economical. Trigger levels for building response were established. Extensive instrumentation was installed and the building was fully monitored during the subsequent phases of tunneling.
    • Download: (896.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Mansion House London: Risk Assessment and Protection

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/81286
    Collections
    • Journal of Construction Engineering and Management

    Show full item record

    contributor authorA. J. Powderham
    contributor authorG. J. Tamaro
    date accessioned2017-05-08T22:28:48Z
    date available2017-05-08T22:28:48Z
    date copyrightSeptember 1995
    date issued1995
    identifier other%28asce%290733-9364%281995%29121%3A3%28266%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/81286
    description abstractSettlements occurring during the first phase of tunneling for the extension of the Docklands Light Railway in London caused concern for damage to the Mansion House during subsequent phases of the work. The building is a landmark structure and no further damage could be accepted. Tunneling was halted until a satisfactory protection program was in place. Various means of protecting the structure were investigated, ranging from full structural underpinning to a least-risk methodology based on the observational method. This paper describes the background to the development and implementation of the observational method to successfully protect the building and complete construction. This required appropriate contingency measures to be identified and planned in advance. Of the contingencies involving preventive or strengthening works, a system of structural ties through the building was selected as most appropriate, least risky, and most economical. Trigger levels for building response were established. Extensive instrumentation was installed and the building was fully monitored during the subsequent phases of tunneling.
    publisherAmerican Society of Civil Engineers
    titleMansion House London: Risk Assessment and Protection
    typeJournal Paper
    journal volume121
    journal issue3
    journal titleJournal of Construction Engineering and Management
    identifier doi10.1061/(ASCE)0733-9364(1995)121:3(266)
    treeJournal of Construction Engineering and Management:;1995:;Volume ( 121 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian