    Archive

    Buckling of Micropiles

    Source: Journal of Geotechnical and Geoenvironmental Engineering:;2007:;Volume ( 133 ):;issue: 003
    Author:
    David R. Shields
    DOI: 10.1061/(ASCE)1090-0241(2007)133:3(334)
    Publisher: American Society of Civil Engineers
    Abstract: Building codes and common design practices generally assume that the lateral support provided by the soil is sufficient to prevent buckling of fully embedded piles. As small diameter grouted piles (micropiles) have evolved from relatively low capacity friction piles to current applications that include high capacity elements, there is a need to revisit the issue of potential buckling of these very slender piles when embedded in soft soils. Pile buckling loads obtained from a semiempirical relationship are compared to the allowable loads permitted by current and proposed codes and design guidelines. It is concluded that buckling is generally not a concern for the most common types of micropile design, but there are some designs permitted under the codes and design guidelines for which buckling may be a controlling design factor.
    • Download: (89.65Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Buckling of Micropiles

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/53113
    Collections
    • Journal of Geotechnical and Geoenvironmental Engineering

    Show full item record

    contributor authorDavid R. Shields
    date accessioned2017-05-08T21:28:52Z
    date available2017-05-08T21:28:52Z
    date copyrightMarch 2007
    date issued2007
    identifier other%28asce%291090-0241%282007%29133%3A3%28334%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/53113
    description abstractBuilding codes and common design practices generally assume that the lateral support provided by the soil is sufficient to prevent buckling of fully embedded piles. As small diameter grouted piles (micropiles) have evolved from relatively low capacity friction piles to current applications that include high capacity elements, there is a need to revisit the issue of potential buckling of these very slender piles when embedded in soft soils. Pile buckling loads obtained from a semiempirical relationship are compared to the allowable loads permitted by current and proposed codes and design guidelines. It is concluded that buckling is generally not a concern for the most common types of micropile design, but there are some designs permitted under the codes and design guidelines for which buckling may be a controlling design factor.
    publisherAmerican Society of Civil Engineers
    titleBuckling of Micropiles
    typeJournal Paper
    journal volume133
    journal issue3
    journal titleJournal of Geotechnical and Geoenvironmental Engineering
    identifier doi10.1061/(ASCE)1090-0241(2007)133:3(334)
    treeJournal of Geotechnical and Geoenvironmental Engineering:;2007:;Volume ( 133 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace