Show simple item record

contributor authorDavid R. Shields
date accessioned2017-05-08T21:28:52Z
date available2017-05-08T21:28:52Z
date copyrightMarch 2007
date issued2007
identifier other%28asce%291090-0241%282007%29133%3A3%28334%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/53113
description abstractBuilding codes and common design practices generally assume that the lateral support provided by the soil is sufficient to prevent buckling of fully embedded piles. As small diameter grouted piles (micropiles) have evolved from relatively low capacity friction piles to current applications that include high capacity elements, there is a need to revisit the issue of potential buckling of these very slender piles when embedded in soft soils. Pile buckling loads obtained from a semiempirical relationship are compared to the allowable loads permitted by current and proposed codes and design guidelines. It is concluded that buckling is generally not a concern for the most common types of micropile design, but there are some designs permitted under the codes and design guidelines for which buckling may be a controlling design factor.
publisherAmerican Society of Civil Engineers
titleBuckling of Micropiles
typeJournal Paper
journal volume133
journal issue3
journal titleJournal of Geotechnical and Geoenvironmental Engineering
identifier doi10.1061/(ASCE)1090-0241(2007)133:3(334)
treeJournal of Geotechnical and Geoenvironmental Engineering:;2007:;Volume ( 133 ):;issue: 003
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record