YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Interacting Multiple-Model Method for Fault Detection and Short Resistance Estimation in Parallel Connected Lithium-Ion Batteries

    Source: Journal of Dynamic Systems, Measurement, and Control:;2026:;volume( 148 ):;issue:002
    Author:
    Movahedi, Hamidreza
    ,
    Ooi, Xin Hui
    ,
    Tran, Vivian V.
    ,
    Jeon, Woongsun
    ,
    Siegel, Jason B.
    ,
    Stefanopoulou, Anna G.
    DOI: 10.1115/1.4070413
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Abstract. Detecting internal short circuits (ISCs) in a single cell connected in parallel with others is challenging because unmeasured internal currents can obscure measurable indicators such as charge loss and voltage drop from the faulty cell. In this work, we propose a new method for detecting ISCs based on the interacting multiple model (IMM) estimation technique, which can provide a probability for the occurrence of an ISC and simultaneously estimate the short-circuit resistance, indicating the severity of the ISC. The IMM relies on dynamic electrothermal models of parallel cells (nP), both for the healthy mode and short-circuit mode. The IMM technique is combined with unscented Kalman filters (UKFs) to detect internal short circuits and estimate the short-circuit resistance across various synthetic data sets that are corrupted by Gaussian noise for different values of ISC resistance. Fifty short-circuit scenarios were simulated in which one cell in a 46 P cell group underwent an ISC during a drive cycle. The short-circuit resistances ranged from 0.5 to 100 Ω, tested at ten different states of charge (SOCs). Our simulation outputs included busbar voltage, input current, and cell temperatures, which were then corrupted by Gaussian noise. Our IMM successfully detected and estimated the ISC in all fifty cases, with temperature rise remaining below 6 °C before detection, well before the onset of thermal runaway conditions.
    • Download: (2.633Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Interacting Multiple-Model Method for Fault Detection and Short Resistance Estimation in Parallel Connected Lithium-Ion Batteries

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4316171
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorMovahedi, Hamidreza
    contributor authorOoi, Xin Hui
    contributor authorTran, Vivian V.
    contributor authorJeon, Woongsun
    contributor authorSiegel, Jason B.
    contributor authorStefanopoulou, Anna G.
    date accessioned2026-08-23T08:10:24Z
    date available2026-08-23T08:10:24Z
    date copyright2026/03/01
    date issued2026
    identifier issn0022-0434
    identifier otherds-25-1200.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4316171
    description abstractAbstract. Detecting internal short circuits (ISCs) in a single cell connected in parallel with others is challenging because unmeasured internal currents can obscure measurable indicators such as charge loss and voltage drop from the faulty cell. In this work, we propose a new method for detecting ISCs based on the interacting multiple model (IMM) estimation technique, which can provide a probability for the occurrence of an ISC and simultaneously estimate the short-circuit resistance, indicating the severity of the ISC. The IMM relies on dynamic electrothermal models of parallel cells (nP), both for the healthy mode and short-circuit mode. The IMM technique is combined with unscented Kalman filters (UKFs) to detect internal short circuits and estimate the short-circuit resistance across various synthetic data sets that are corrupted by Gaussian noise for different values of ISC resistance. Fifty short-circuit scenarios were simulated in which one cell in a 46 P cell group underwent an ISC during a drive cycle. The short-circuit resistances ranged from 0.5 to 100 Ω, tested at ten different states of charge (SOCs). Our simulation outputs included busbar voltage, input current, and cell temperatures, which were then corrupted by Gaussian noise. Our IMM successfully detected and estimated the ISC in all fifty cases, with temperature rise remaining below 6 °C before detection, well before the onset of thermal runaway conditions.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInteracting Multiple-Model Method for Fault Detection and Short Resistance Estimation in Parallel Connected Lithium-Ion Batteries
    typeJournal Paper
    journal volume148
    journal issue2
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.4070413
    treeJournal of Dynamic Systems, Measurement, and Control:;2026:;volume( 148 ):;issue:002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian