Effect of Working Fluid, Orientation, and Cooling Mode on Thermal Performance of Miniature Flat Heat PipeSource: Journal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 009::page 91011-1DOI: 10.1115/1.4062920Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Flat heat pipes (FHPs) are commonly used as a passive cooling system in portable electronic gadgets due to their compact profile. The present study investigates the effect of different working fluids on the thermal performance of a miniature FHP under different orientations and condenser cooling mechanisms and the start-up performance of FHP. Deionized water, acetone, ethanol, and methanol are chosen as working fluids in the FHP. Five different inclinations (0 deg (horizontal), 30 deg, 45 deg, 60 deg, and 90 deg (vertical)) and two different condenser cooling methods (natural convection and forced convection with fan cooling) are considered in this experimental study. The FHP thermal performance is quantified in terms of overall temperature difference, thermal resistance, and effective thermal conductivity. The results indicate that comparatively higher effective thermal conductivity values are obtained for methanol and acetone heat pipes at low heat loads and under natural convection. At higher heat loads, the ethanol heat pipe had higher effective thermal conductivity values for the same condenser cooling method. For the case of the forced convection cooling mode, the methanol heat pipe had enhanced thermal performance as compared to the other three fluids for all heat load ranges and different inclinations. Due to the higher boiling point of water, as a working fluid water is not suitable in most of the experimental trials except at high heat load under forced convection cooling and in a horizontal orientation. The maximum effective thermal conductivity of 7846 W/mK is obtained for FHP filled with methanol at 24 W heat load and 90 deg orientation under forced convection condenser cooling.
|
Show full item record
| contributor author | Rathod, Jigneshsinh | |
| contributor author | Lakhera, Vikas | |
| contributor author | Shukla, Atindra | |
| date accessioned | 2023-11-29T19:45:13Z | |
| date available | 2023-11-29T19:45:13Z | |
| date copyright | 7/27/2023 12:00:00 AM | |
| date issued | 7/27/2023 12:00:00 AM | |
| date issued | 2023-07-27 | |
| identifier issn | 1948-5085 | |
| identifier other | tsea_15_9_091011.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4295004 | |
| description abstract | Flat heat pipes (FHPs) are commonly used as a passive cooling system in portable electronic gadgets due to their compact profile. The present study investigates the effect of different working fluids on the thermal performance of a miniature FHP under different orientations and condenser cooling mechanisms and the start-up performance of FHP. Deionized water, acetone, ethanol, and methanol are chosen as working fluids in the FHP. Five different inclinations (0 deg (horizontal), 30 deg, 45 deg, 60 deg, and 90 deg (vertical)) and two different condenser cooling methods (natural convection and forced convection with fan cooling) are considered in this experimental study. The FHP thermal performance is quantified in terms of overall temperature difference, thermal resistance, and effective thermal conductivity. The results indicate that comparatively higher effective thermal conductivity values are obtained for methanol and acetone heat pipes at low heat loads and under natural convection. At higher heat loads, the ethanol heat pipe had higher effective thermal conductivity values for the same condenser cooling method. For the case of the forced convection cooling mode, the methanol heat pipe had enhanced thermal performance as compared to the other three fluids for all heat load ranges and different inclinations. Due to the higher boiling point of water, as a working fluid water is not suitable in most of the experimental trials except at high heat load under forced convection cooling and in a horizontal orientation. The maximum effective thermal conductivity of 7846 W/mK is obtained for FHP filled with methanol at 24 W heat load and 90 deg orientation under forced convection condenser cooling. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Effect of Working Fluid, Orientation, and Cooling Mode on Thermal Performance of Miniature Flat Heat Pipe | |
| type | Journal Paper | |
| journal volume | 15 | |
| journal issue | 9 | |
| journal title | Journal of Thermal Science and Engineering Applications | |
| identifier doi | 10.1115/1.4062920 | |
| journal fristpage | 91011-1 | |
| journal lastpage | 91011-11 | |
| page | 11 | |
| tree | Journal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 009 | |
| contenttype | Fulltext |