Show simple item record

contributor authorRathod, Jigneshsinh
contributor authorLakhera, Vikas
contributor authorShukla, Atindra
date accessioned2023-11-29T19:45:13Z
date available2023-11-29T19:45:13Z
date copyright7/27/2023 12:00:00 AM
date issued7/27/2023 12:00:00 AM
date issued2023-07-27
identifier issn1948-5085
identifier othertsea_15_9_091011.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4295004
description abstractFlat heat pipes (FHPs) are commonly used as a passive cooling system in portable electronic gadgets due to their compact profile. The present study investigates the effect of different working fluids on the thermal performance of a miniature FHP under different orientations and condenser cooling mechanisms and the start-up performance of FHP. Deionized water, acetone, ethanol, and methanol are chosen as working fluids in the FHP. Five different inclinations (0 deg (horizontal), 30 deg, 45 deg, 60 deg, and 90 deg (vertical)) and two different condenser cooling methods (natural convection and forced convection with fan cooling) are considered in this experimental study. The FHP thermal performance is quantified in terms of overall temperature difference, thermal resistance, and effective thermal conductivity. The results indicate that comparatively higher effective thermal conductivity values are obtained for methanol and acetone heat pipes at low heat loads and under natural convection. At higher heat loads, the ethanol heat pipe had higher effective thermal conductivity values for the same condenser cooling method. For the case of the forced convection cooling mode, the methanol heat pipe had enhanced thermal performance as compared to the other three fluids for all heat load ranges and different inclinations. Due to the higher boiling point of water, as a working fluid water is not suitable in most of the experimental trials except at high heat load under forced convection cooling and in a horizontal orientation. The maximum effective thermal conductivity of 7846 W/mK is obtained for FHP filled with methanol at 24 W heat load and 90 deg orientation under forced convection condenser cooling.
publisherThe American Society of Mechanical Engineers (ASME)
titleEffect of Working Fluid, Orientation, and Cooling Mode on Thermal Performance of Miniature Flat Heat Pipe
typeJournal Paper
journal volume15
journal issue9
journal titleJournal of Thermal Science and Engineering Applications
identifier doi10.1115/1.4062920
journal fristpage91011-1
journal lastpage91011-11
page11
treeJournal of Thermal Science and Engineering Applications:;2023:;volume( 015 ):;issue: 009
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record