    Development of an Endotracheal Tube Cap for Oxygen Delivery During Intubation

    Source: Journal of Medical Devices:;2023:;volume( 017 ):;issue: 002::page 24502-1
    Author:
    Hart, Keir
    ,
    Salvino, Chris
    ,
    Pashak, Todd
    ,
    Veatch, Brad
    DOI: 10.1115/1.4062151
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Endotracheal (ET) Intubation is a medical procedure whereupon a physician or trained personnel inserts a breathing tube into a patient's mouth, through their vocal cords, and into their trachea. Intubation can be lifesaving when a patient cannot breathe on their own. Intubations are performed routinely, with approximately 15 × 106 performed annually just in the operating room (OR) with an additional 650,000 intubations in the wider hospital environment. Intubation is a complex, dynamic, and at times difficult procedure with major consequences if delayed and/or if the procedure fails. Complications for intubations outside of the operating room are reported as high as 27%, with the most common being hypoxia, or low oxygen levels. We have developed a simple, sterile attachment that directs oxygen down endotracheal tubes during intubation. Benchtop studies have demonstrated acceptable pressures well below those leading to barotrauma. In animal studies, the device has been shown to significantly reduce hypoxia; thereby increasing the time a medical provider has to safely perform the procedure. While further development is warranted, as well as additional testing both in vitro and in vivo, the cap assembly appears to provide a viable solution to a persistent and dangerous problem in medicine.
    • Download: (718.3Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Development of an Endotracheal Tube Cap for Oxygen Delivery During Intubation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4292438
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorHart, Keir
    contributor authorSalvino, Chris
    contributor authorPashak, Todd
    contributor authorVeatch, Brad
    date accessioned2023-08-16T18:45:19Z
    date available2023-08-16T18:45:19Z
    date copyright4/17/2023 12:00:00 AM
    date issued2023
    identifier issn1932-6181
    identifier othermed_017_02_024502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4292438
    description abstractEndotracheal (ET) Intubation is a medical procedure whereupon a physician or trained personnel inserts a breathing tube into a patient's mouth, through their vocal cords, and into their trachea. Intubation can be lifesaving when a patient cannot breathe on their own. Intubations are performed routinely, with approximately 15 × 106 performed annually just in the operating room (OR) with an additional 650,000 intubations in the wider hospital environment. Intubation is a complex, dynamic, and at times difficult procedure with major consequences if delayed and/or if the procedure fails. Complications for intubations outside of the operating room are reported as high as 27%, with the most common being hypoxia, or low oxygen levels. We have developed a simple, sterile attachment that directs oxygen down endotracheal tubes during intubation. Benchtop studies have demonstrated acceptable pressures well below those leading to barotrauma. In animal studies, the device has been shown to significantly reduce hypoxia; thereby increasing the time a medical provider has to safely perform the procedure. While further development is warranted, as well as additional testing both in vitro and in vivo, the cap assembly appears to provide a viable solution to a persistent and dangerous problem in medicine.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment of an Endotracheal Tube Cap for Oxygen Delivery During Intubation
    typeJournal Paper
    journal volume17
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4062151
    journal fristpage24502-1
    journal lastpage24502-6
    page6
    treeJournal of Medical Devices:;2023:;volume( 017 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian