YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Applied Mechanics
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Applied Mechanics
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    An Intracortical Polyimide Microprobe With Piezoelectric-Based Stiffness Control

    Source: Journal of Applied Mechanics:;2022:;volume( 089 ):;issue: 009::page 91008
    Author:
    Sharafkhani, Naser;Orwa, Julius O.;Adams, Scott D.;Long, John M.;Lissorgues, Gaëlle;Rousseau, Lionel;Kouzani, Abbas Z.
    DOI: 10.1115/1.4054979
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Insertion of a microprobe into the brain is challenging because it needs to have a minimum stiffness to be successfully implanted and a maximum softness to exhibit compliance with surrounding neural tissue during operation. A microprobe’s critical buckling force not only dictates the microprobe resistance to buckling during insertion but also reveals the corresponding compliance during operation. The methods that are currently used to insert flexible microprobes into the brain are far from perfect because they may adversely affect the microprobe intrinsic softness. In this article, a piezoelectric-based mechanism is presented, theoretically modeled, and simulated to precisely adjust the critical buckling force of a polyimide microprobe during insertion into the brain. Two parallel piezoelectric layers are extended along the length of a polyimide microprobe and connected to a voltage source. Based on analytical modeling and simulation results, placing the piezoelectric layers closer to the neutral axis of the structure leads to a microprobe with higher buckling capacity and greater compliance during insertion and operation, respectively. Depending on the applied voltage and the configurations of the microprobe and piezoelectric layers, the critical buckling force of the modified polyimide microprobe can be adjusted from less than 0.02 mN to higher than the minimum brain penetration force of 0.5 mN, compared to a fixed critical buckling force of a polyimide microprobe without the piezoelectric layer.
    • Download: (601.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      An Intracortical Polyimide Microprobe With Piezoelectric-Based Stiffness Control

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4288109
    Collections
    • Journal of Applied Mechanics

    Show full item record

    contributor authorSharafkhani, Naser;Orwa, Julius O.;Adams, Scott D.;Long, John M.;Lissorgues, Gaëlle;Rousseau, Lionel;Kouzani, Abbas Z.
    date accessioned2022-12-27T23:12:25Z
    date available2022-12-27T23:12:25Z
    date copyright7/28/2022 12:00:00 AM
    date issued2022
    identifier issn0021-8936
    identifier otherjam_89_9_091008.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4288109
    description abstractInsertion of a microprobe into the brain is challenging because it needs to have a minimum stiffness to be successfully implanted and a maximum softness to exhibit compliance with surrounding neural tissue during operation. A microprobe’s critical buckling force not only dictates the microprobe resistance to buckling during insertion but also reveals the corresponding compliance during operation. The methods that are currently used to insert flexible microprobes into the brain are far from perfect because they may adversely affect the microprobe intrinsic softness. In this article, a piezoelectric-based mechanism is presented, theoretically modeled, and simulated to precisely adjust the critical buckling force of a polyimide microprobe during insertion into the brain. Two parallel piezoelectric layers are extended along the length of a polyimide microprobe and connected to a voltage source. Based on analytical modeling and simulation results, placing the piezoelectric layers closer to the neutral axis of the structure leads to a microprobe with higher buckling capacity and greater compliance during insertion and operation, respectively. Depending on the applied voltage and the configurations of the microprobe and piezoelectric layers, the critical buckling force of the modified polyimide microprobe can be adjusted from less than 0.02 mN to higher than the minimum brain penetration force of 0.5 mN, compared to a fixed critical buckling force of a polyimide microprobe without the piezoelectric layer.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Intracortical Polyimide Microprobe With Piezoelectric-Based Stiffness Control
    typeJournal Paper
    journal volume89
    journal issue9
    journal titleJournal of Applied Mechanics
    identifier doi10.1115/1.4054979
    journal fristpage91008
    journal lastpage91008_8
    page8
    treeJournal of Applied Mechanics:;2022:;volume( 089 ):;issue: 009
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian