    Development and Validation of a Physiological Testing Method for Sternal Closure Systems

    Source: Journal of Medical Devices:;2022:;volume( 016 ):;issue: 002::page 21011-1
    Author:
    Kienle
    ,
    Annette;Renner
    ,
    Nadine;Bischoff
    ,
    Constanze
    DOI: 10.1115/1.4053687
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: After a median sternotomy, the sternum has to be refixated using implants such as wires, plates, or clamps. However, there is still a lack of specifically applicable test methods to investigate the mechanical safety and effectiveness of such implant systems. The aim of this study was to develop a new test method that replicates the in vivo loads acting on the sternum and that is applicable to all types of sternal closure systems. Based on the scientific literature, a setup was developed that incorporates the physiological loads acting on the sternum during breathing (91 N) and coughing (328 N). These loads are applied to a sternum replicate at 5 Hz for approximately 1.8 × 106 cycles. This cycle number is assumed to represent the healing period. For validation, the new method was applied to two different sternal closure systems: a PEEK clamp system and wires. The new test method proved to be easily applicable. The validation tests with the two sternal closure systems showed reasonable and reproducible results regarding all outcome parameters. The pretension exerted by the implants significantly differed between the two implant groups and decreased after the first coughing cycles. The fracture gap separation during breathing also significantly different between the two test groups, but it was similar during coughing. No implant failed. Using this new test method, it is possible to compare sternal closure systems under reproducible, in vivo-based conditions and interpret their mechanical characteristics regarding their clinical safety and effectiveness.
    • Download: (1.199Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Development and Validation of a Physiological Testing Method for Sternal Closure Systems

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4286964
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorKienle
    contributor authorAnnette;Renner
    contributor authorNadine;Bischoff
    contributor authorConstanze
    date accessioned2022-08-18T12:50:49Z
    date available2022-08-18T12:50:49Z
    date copyright3/2/2022 12:00:00 AM
    date issued2022
    identifier issn1932-6181
    identifier othermed_016_02_021011.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4286964
    description abstractAfter a median sternotomy, the sternum has to be refixated using implants such as wires, plates, or clamps. However, there is still a lack of specifically applicable test methods to investigate the mechanical safety and effectiveness of such implant systems. The aim of this study was to develop a new test method that replicates the in vivo loads acting on the sternum and that is applicable to all types of sternal closure systems. Based on the scientific literature, a setup was developed that incorporates the physiological loads acting on the sternum during breathing (91 N) and coughing (328 N). These loads are applied to a sternum replicate at 5 Hz for approximately 1.8 × 106 cycles. This cycle number is assumed to represent the healing period. For validation, the new method was applied to two different sternal closure systems: a PEEK clamp system and wires. The new test method proved to be easily applicable. The validation tests with the two sternal closure systems showed reasonable and reproducible results regarding all outcome parameters. The pretension exerted by the implants significantly differed between the two implant groups and decreased after the first coughing cycles. The fracture gap separation during breathing also significantly different between the two test groups, but it was similar during coughing. No implant failed. Using this new test method, it is possible to compare sternal closure systems under reproducible, in vivo-based conditions and interpret their mechanical characteristics regarding their clinical safety and effectiveness.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment and Validation of a Physiological Testing Method for Sternal Closure Systems
    typeJournal Paper
    journal volume16
    journal issue2
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4053687
    journal fristpage21011-1
    journal lastpage21011-6
    page6
    treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian