description abstractAfter a median sternotomy, the sternum has to be refixated using implants such as wires, plates, or clamps. However, there is still a lack of specifically applicable test methods to investigate the mechanical safety and effectiveness of such implant systems. The aim of this study was to develop a new test method that replicates the in vivo loads acting on the sternum and that is applicable to all types of sternal closure systems. Based on the scientific literature, a setup was developed that incorporates the physiological loads acting on the sternum during breathing (91 N) and coughing (328 N). These loads are applied to a sternum replicate at 5 Hz for approximately 1.8 × 106 cycles. This cycle number is assumed to represent the healing period. For validation, the new method was applied to two different sternal closure systems: a PEEK clamp system and wires. The new test method proved to be easily applicable. The validation tests with the two sternal closure systems showed reasonable and reproducible results regarding all outcome parameters. The pretension exerted by the implants significantly differed between the two implant groups and decreased after the first coughing cycles. The fracture gap separation during breathing also significantly different between the two test groups, but it was similar during coughing. No implant failed. Using this new test method, it is possible to compare sternal closure systems under reproducible, in vivo-based conditions and interpret their mechanical characteristics regarding their clinical safety and effectiveness.
publisherThe American Society of Mechanical Engineers (ASME)
titleDevelopment and Validation of a Physiological Testing Method for Sternal Closure Systems
typeJournal Paper
journal volume16
journal issue2
journal titleJournal of Medical Devices
identifier doi10.1115/1.4053687
journal fristpage21011-1
journal lastpage21011-6
page6
treeJournal of Medical Devices:;2022:;volume( 016 ):;issue: 002
contenttypeFulltext