YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Medical Devices
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    VEMERS UC: A Clinically Validated Emergency Mechanical Ventilator for COVID-19 and Postpandemic Use in Low Resource Communities

    Source: Journal of Medical Devices:;2021:;volume( 015 ):;issue: 003::page 031008-1
    Author:
    Chiang, Luciano E.
    ,
    Castro, Felipe A.
    DOI: 10.1115/1.4051246
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In this article, we present a clinically validated invasive emergency mechanical ventilator developed in Chile called VEMERS UC. It has been clinically tested and validated in intubated Covid-19 patients. Once the pandemic hit Chilean soil in March 2020, it was quite clear that the number of mechanical ventilators available would not be enough. As in other parts of the world many initiatives sprung, most of them naively simple. Chilean medical societies joined engineering specialists and agreed early on in an organized and regulated open process for validating emergency mechanical ventilators, thus allowing for rapid development but with the required functionality, reliability, and safety features. VEMERS UC was one of a few that completed successfully all stages of the validating process, the final test being on five critically ill intubated Covid-19 patients for eight hours each. VEMERS UC is based on an electropneumatic circuit architecture, and its components are all low cost, off-the-shelf pneumatic, and electronic products easily obtained in industrial markets. It works in continuous mandatory volume control mode. The novel technical features of VEMERS UC are discussed here as well as the results obtained in each stage of the validating process. The validating process carried out in Chile is noteworthy by itself, and it could be used as an example in other developing countries. Furthermore, VEMERS UC can be used as a guiding design reference in other countries as well, since this design has already been thoroughly tested in human patients and has proven to work successfully.
    • Download: (2.352Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      VEMERS UC: A Clinically Validated Emergency Mechanical Ventilator for COVID-19 and Postpandemic Use in Low Resource Communities

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4278729
    Collections
    • Journal of Medical Devices

    Show full item record

    contributor authorChiang, Luciano E.
    contributor authorCastro, Felipe A.
    date accessioned2022-02-06T05:46:27Z
    date available2022-02-06T05:46:27Z
    date copyright6/25/2021 12:00:00 AM
    date issued2021
    identifier issn1932-6181
    identifier othermed_015_03_031008.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4278729
    description abstractIn this article, we present a clinically validated invasive emergency mechanical ventilator developed in Chile called VEMERS UC. It has been clinically tested and validated in intubated Covid-19 patients. Once the pandemic hit Chilean soil in March 2020, it was quite clear that the number of mechanical ventilators available would not be enough. As in other parts of the world many initiatives sprung, most of them naively simple. Chilean medical societies joined engineering specialists and agreed early on in an organized and regulated open process for validating emergency mechanical ventilators, thus allowing for rapid development but with the required functionality, reliability, and safety features. VEMERS UC was one of a few that completed successfully all stages of the validating process, the final test being on five critically ill intubated Covid-19 patients for eight hours each. VEMERS UC is based on an electropneumatic circuit architecture, and its components are all low cost, off-the-shelf pneumatic, and electronic products easily obtained in industrial markets. It works in continuous mandatory volume control mode. The novel technical features of VEMERS UC are discussed here as well as the results obtained in each stage of the validating process. The validating process carried out in Chile is noteworthy by itself, and it could be used as an example in other developing countries. Furthermore, VEMERS UC can be used as a guiding design reference in other countries as well, since this design has already been thoroughly tested in human patients and has proven to work successfully.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleVEMERS UC: A Clinically Validated Emergency Mechanical Ventilator for COVID-19 and Postpandemic Use in Low Resource Communities
    typeJournal Paper
    journal volume15
    journal issue3
    journal titleJournal of Medical Devices
    identifier doi10.1115/1.4051246
    journal fristpage031008-1
    journal lastpage031008-12
    page12
    treeJournal of Medical Devices:;2021:;volume( 015 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian