| contributor author | Nanda, Biswamohan | |
| contributor author | Madhavi, Voleti | |
| contributor author | Suguna Devi, S. V. | |
| contributor author | Balachandran, R. | |
| date accessioned | 2022-02-05T21:54:42Z | |
| date available | 2022-02-05T21:54:42Z | |
| date copyright | 4/16/2021 12:00:00 AM | |
| date issued | 2021 | |
| identifier issn | 2332-8983 | |
| identifier other | ners_007_04_042001.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4276559 | |
| description abstract | While processing the signals from radiation detectors, for finding the true mean-count-rate, algorithms with hybrid pulse collection methodology have been proposed and used over the years. An algorithm based on this technique with a new methodology of adoption and implementation including spurious rejection is proposed here. It enables a specified and controllable error when the mean-count-rate remains within certain predefined limits from its true value. Effort is made to optimize the response time of prediction at low count rates preserving the optimum possible relative-standard-deviation (RSD). Chi-squared test is utilized for verifying the counting system to check if the observed fluctuations are consistent with the expected statistical fluctuations. A C-program code has been developed to test the algorithm. An observed set of detector outputs are given as input to the program and the corresponding Output is analyzed. A comparative study between the proposed method and floating-mean method is presented for the same set of observations. A typical short-lived high voltage (HV) induced spurious noise pattern is fed as input to the program verifying limited-spurious rejection capability of the algorithm. An embedded C program was written for microcontroller implementation of the algorithm. Case-study of a neutron roentgen equivalent man (REM) counter is presented for evaluating response time for various ranges of operation with calculation of RSD at these ranges. This general-purpose algorithm can enhance the read-out accuracy of radiation monitors used for radiation safety applications. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Simplified Algorithm for Count Rate Processing in Radiation Monitors That Address Statistical Fluctuations and Spurious Counts | |
| type | Journal Paper | |
| journal volume | 7 | |
| journal issue | 4 | |
| journal title | Journal of Nuclear Engineering and Radiation Science | |
| identifier doi | 10.1115/1.4050215 | |
| journal fristpage | 042001-1 | |
| journal lastpage | 042001-9 | |
| page | 9 | |
| tree | Journal of Nuclear Engineering and Radiation Science:;2021:;volume( 007 ):;issue: 004 | |
| contenttype | Fulltext | |