description abstractWhile processing the signals from radiation detectors, for finding the true mean-count-rate, algorithms with hybrid pulse collection methodology have been proposed and used over the years. An algorithm based on this technique with a new methodology of adoption and implementation including spurious rejection is proposed here. It enables a specified and controllable error when the mean-count-rate remains within certain predefined limits from its true value. Effort is made to optimize the response time of prediction at low count rates preserving the optimum possible relative-standard-deviation (RSD). Chi-squared test is utilized for verifying the counting system to check if the observed fluctuations are consistent with the expected statistical fluctuations. A C-program code has been developed to test the algorithm. An observed set of detector outputs are given as input to the program and the corresponding Output is analyzed. A comparative study between the proposed method and floating-mean method is presented for the same set of observations. A typical short-lived high voltage (HV) induced spurious noise pattern is fed as input to the program verifying limited-spurious rejection capability of the algorithm. An embedded C program was written for microcontroller implementation of the algorithm. Case-study of a neutron roentgen equivalent man (REM) counter is presented for evaluating response time for various ranges of operation with calculation of RSD at these ranges. This general-purpose algorithm can enhance the read-out accuracy of radiation monitors used for radiation safety applications.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Simplified Algorithm for Count Rate Processing in Radiation Monitors That Address Statistical Fluctuations and Spurious Counts
typeJournal Paper
journal volume7
journal issue4
journal titleJournal of Nuclear Engineering and Radiation Science
identifier doi10.1115/1.4050215
journal fristpage042001-1
journal lastpage042001-9
page9
treeJournal of Nuclear Engineering and Radiation Science:;2021:;volume( 007 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record