    Simultaneous Extraction of Multiple Parameters From a Transmit–Receive Eddy Current Probe Above a Layered Planar Conductive Structure

    Source: Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems:;2020:;volume( 003 ):;issue: 004::page 041104-1
    Author:
    Luloff, Mark S.
    ,
    Contant, Stephane
    ,
    Morelli, Jordan
    ,
    Krause, Thomas W.
    DOI: 10.1115/1.4047293
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A validated analytical model of a transmit–receive coil pair situated above two parallel plates, separated by an air gap, was used as the basis for an inversion algorithm (IA) to extract probe liftoff, second layer plate resistivity, and plate-to-plate gap from multi-frequency eddy current data. The IA was tested over a large range of first layer wall thickness (3.80–4.64 mm), second layer plate resistivity (1.7–174 µΩ cm), second layer wall thickness (1.20–4.85 mm), probe liftoff (2.8–7.9 mm), and plate-to-plate gap (0–13.3 mm). At nominal liftoff (2.8 mm), the IA achieved a gap measurement accuracy of ±0.7 mm and was able to return good estimates of the second layer resistivity within ±1 μΩ cm for low resistivity samples, but with decreasing accuracy for higher resistivities. When the gap was fixed, the IA was able to measure changes in probe liftoff (relative to nominal) to an accuracy of ±0.2 mm. The reported accuracy and a demonstration for the ability to accurately estimate parameters outside of the calibration range provide confidence in the potential utility of the algorithm.
    • Download: (345.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Simultaneous Extraction of Multiple Parameters From a Transmit–Receive Eddy Current Probe Above a Layered Planar Conductive Structure

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4275209
    Collections
    • Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems

    Show full item record

    contributor authorLuloff, Mark S.
    contributor authorContant, Stephane
    contributor authorMorelli, Jordan
    contributor authorKrause, Thomas W.
    date accessioned2022-02-04T22:15:41Z
    date available2022-02-04T22:15:41Z
    date copyright6/26/2020 12:00:00 AM
    date issued2020
    identifier issn2572-3901
    identifier othernde_3_4_041104.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4275209
    description abstractA validated analytical model of a transmit–receive coil pair situated above two parallel plates, separated by an air gap, was used as the basis for an inversion algorithm (IA) to extract probe liftoff, second layer plate resistivity, and plate-to-plate gap from multi-frequency eddy current data. The IA was tested over a large range of first layer wall thickness (3.80–4.64 mm), second layer plate resistivity (1.7–174 µΩ cm), second layer wall thickness (1.20–4.85 mm), probe liftoff (2.8–7.9 mm), and plate-to-plate gap (0–13.3 mm). At nominal liftoff (2.8 mm), the IA achieved a gap measurement accuracy of ±0.7 mm and was able to return good estimates of the second layer resistivity within ±1 μΩ cm for low resistivity samples, but with decreasing accuracy for higher resistivities. When the gap was fixed, the IA was able to measure changes in probe liftoff (relative to nominal) to an accuracy of ±0.2 mm. The reported accuracy and a demonstration for the ability to accurately estimate parameters outside of the calibration range provide confidence in the potential utility of the algorithm.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSimultaneous Extraction of Multiple Parameters From a Transmit–Receive Eddy Current Probe Above a Layered Planar Conductive Structure
    typeJournal Paper
    journal volume3
    journal issue4
    journal titleJournal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
    identifier doi10.1115/1.4047293
    journal fristpage041104-1
    journal lastpage041104-5
    page5
    treeJournal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems:;2020:;volume( 003 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian