    Modeling and Experimental Validation of a Reed Check Valve for Hydraulic Applications

    Source: Journal of Dynamic Systems, Measurement, and Control:;2020:;volume( 142 ):;issue: 011::page 0111001-1
    Author:
    Knutson, Anthony L.
    ,
    Van de Ven, James D.
    DOI: 10.1115/1.4047450
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Reed valves are a type of check valve commonly found in a wide range of applications including air compressors, internal combustion engines, musical instruments, and even the human heart. While reed valves have been studied extensively in these applications, published research on the modeling and application of reed valves in hydraulic systems is sparse. Because the spring and mass components of a reed valve are contained in a single element, it is light and compact compared to traditional disk, poppet, or ball style check valves. These advantages make reed valves promising for use in high-frequency applications such as piston pumps, switch-mode hydraulics, and digital hydraulics. Furthermore, the small size and fast response of reed valves provide an opportunity to design pumps capable of operating at higher speeds and with lower dead volumes, thus increasing efficiency and power density. In this paper, a modeling technique for reed valves is presented and validated in a hydraulic piston pump test bed. Excellent agreement between modeled and experimentally measured reed valve opening is demonstrated. Across the range of experimental conditions, the model predicts the pump delivery with an error typically less than 1% with a maximum error of 2.2%.
    • Download: (542.0Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Modeling and Experimental Validation of a Reed Check Valve for Hydraulic Applications

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4274557
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorKnutson, Anthony L.
    contributor authorVan de Ven, James D.
    date accessioned2022-02-04T21:56:02Z
    date available2022-02-04T21:56:02Z
    date copyright6/29/2020 12:00:00 AM
    date issued2020
    identifier issn0022-0434
    identifier otherds_142_11_114501.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274557
    description abstractReed valves are a type of check valve commonly found in a wide range of applications including air compressors, internal combustion engines, musical instruments, and even the human heart. While reed valves have been studied extensively in these applications, published research on the modeling and application of reed valves in hydraulic systems is sparse. Because the spring and mass components of a reed valve are contained in a single element, it is light and compact compared to traditional disk, poppet, or ball style check valves. These advantages make reed valves promising for use in high-frequency applications such as piston pumps, switch-mode hydraulics, and digital hydraulics. Furthermore, the small size and fast response of reed valves provide an opportunity to design pumps capable of operating at higher speeds and with lower dead volumes, thus increasing efficiency and power density. In this paper, a modeling technique for reed valves is presented and validated in a hydraulic piston pump test bed. Excellent agreement between modeled and experimentally measured reed valve opening is demonstrated. Across the range of experimental conditions, the model predicts the pump delivery with an error typically less than 1% with a maximum error of 2.2%.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleModeling and Experimental Validation of a Reed Check Valve for Hydraulic Applications
    typeJournal Paper
    journal volume142
    journal issue11
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.4047450
    journal fristpage0111001-1
    journal lastpage0111001-7
    page7
    treeJournal of Dynamic Systems, Measurement, and Control:;2020:;volume( 142 ):;issue: 011
    contenttypeFulltext