Quantification of Passive Ventilation Produced by Manual Chest Compressions Using a New Cardiopulmonary Resuscitation Feedback DeviceSource: Journal of Medical Devices:;2020:;volume( 014 ):;issue: 002Author:Taleb, Lhoucine Ben
,
Essoukaki, Elmaati
,
Mouhsen, Azeddine
,
Lyazidi, Aissam
,
Assir, Abdelhadi
,
Harmouchi, Mohammed
,
Rattal, Mourad
DOI: 10.1115/1.4046512Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Several studies have shown that chest compressions (CC) alone may produce in addition to blood circulation, a short-term passive ventilation. However, it is not clear whether high CC quality may produce in even greater amount of ventilation volumes. The aim of this study was to evaluate whether CC, using a new feedback device, can produce a substantial and sustainable passive volumes compared to standard CC. Thirty inexperienced volunteers performed CC for 2 min on a developed thoracic lung model and using a new feedback device. Participants were randomized into two groups that performed either CC with feedback first, followed by a trial without feedback, or vice versa. Efficient compression rate (correct CC rate and depth simultaneously) was significantly higher in feedback session (43.6% versus 25.5%; P = 0.006). As well, CC rate and depth efficiency were improved with feedback. Moreover, average tidal volumes and minute volumes that occurred during CC alone were significantly improved in feedback session (79.8 ± 5 ml versus 72.9 ± 7 ml) and (8.8 l/min versus 7.9 l/min), respectively (P < 0.001). Yet, no significant difference was found between the first and the 90th second interval (9.04 l/min versus 8.68 l/min, P = 0.163) in the feedback session. Conversely, a significant difference was evident after the first 15th seconds interval without feedback (8.77 l/min initially versus 8.38 l/min; P = 0.041). This study revealed that the new CPR feedback device improved CC quality in inexperienced volunteers. As well, the passive ventilation volumes were significantly increased and sustained when the device was used.
|
Collections
Show full item record
| contributor author | Taleb, Lhoucine Ben | |
| contributor author | Essoukaki, Elmaati | |
| contributor author | Mouhsen, Azeddine | |
| contributor author | Lyazidi, Aissam | |
| contributor author | Assir, Abdelhadi | |
| contributor author | Harmouchi, Mohammed | |
| contributor author | Rattal, Mourad | |
| date accessioned | 2022-02-04T14:28:20Z | |
| date available | 2022-02-04T14:28:20Z | |
| date copyright | 2020/03/13/ | |
| date issued | 2020 | |
| identifier issn | 1932-6181 | |
| identifier other | med_014_02_024503.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4273723 | |
| description abstract | Several studies have shown that chest compressions (CC) alone may produce in addition to blood circulation, a short-term passive ventilation. However, it is not clear whether high CC quality may produce in even greater amount of ventilation volumes. The aim of this study was to evaluate whether CC, using a new feedback device, can produce a substantial and sustainable passive volumes compared to standard CC. Thirty inexperienced volunteers performed CC for 2 min on a developed thoracic lung model and using a new feedback device. Participants were randomized into two groups that performed either CC with feedback first, followed by a trial without feedback, or vice versa. Efficient compression rate (correct CC rate and depth simultaneously) was significantly higher in feedback session (43.6% versus 25.5%; P = 0.006). As well, CC rate and depth efficiency were improved with feedback. Moreover, average tidal volumes and minute volumes that occurred during CC alone were significantly improved in feedback session (79.8 ± 5 ml versus 72.9 ± 7 ml) and (8.8 l/min versus 7.9 l/min), respectively (P < 0.001). Yet, no significant difference was found between the first and the 90th second interval (9.04 l/min versus 8.68 l/min, P = 0.163) in the feedback session. Conversely, a significant difference was evident after the first 15th seconds interval without feedback (8.77 l/min initially versus 8.38 l/min; P = 0.041). This study revealed that the new CPR feedback device improved CC quality in inexperienced volunteers. As well, the passive ventilation volumes were significantly increased and sustained when the device was used. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | Quantification of Passive Ventilation Produced by Manual Chest Compressions Using a New Cardiopulmonary Resuscitation Feedback Device | |