Show simple item record

contributor authorTaleb, Lhoucine Ben
contributor authorEssoukaki, Elmaati
contributor authorMouhsen, Azeddine
contributor authorLyazidi, Aissam
contributor authorAssir, Abdelhadi
contributor authorHarmouchi, Mohammed
contributor authorRattal, Mourad
date accessioned2022-02-04T14:28:20Z
date available2022-02-04T14:28:20Z
date copyright2020/03/13/
date issued2020
identifier issn1932-6181
identifier othermed_014_02_024503.pdf
identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4273723
description abstractSeveral studies have shown that chest compressions (CC) alone may produce in addition to blood circulation, a short-term passive ventilation. However, it is not clear whether high CC quality may produce in even greater amount of ventilation volumes. The aim of this study was to evaluate whether CC, using a new feedback device, can produce a substantial and sustainable passive volumes compared to standard CC. Thirty inexperienced volunteers performed CC for 2 min on a developed thoracic lung model and using a new feedback device. Participants were randomized into two groups that performed either CC with feedback first, followed by a trial without feedback, or vice versa. Efficient compression rate (correct CC rate and depth simultaneously) was significantly higher in feedback session (43.6% versus 25.5%; P = 0.006). As well, CC rate and depth efficiency were improved with feedback. Moreover, average tidal volumes and minute volumes that occurred during CC alone were significantly improved in feedback session (79.8 ± 5 ml versus 72.9 ± 7 ml) and (8.8 l/min versus 7.9 l/min), respectively (P < 0.001). Yet, no significant difference was found between the first and the 90th second interval (9.04 l/min versus 8.68 l/min, P = 0.163) in the feedback session. Conversely, a significant difference was evident after the first 15th seconds interval without feedback (8.77 l/min initially versus 8.38 l/min; P = 0.041). This study revealed that the new CPR feedback device improved CC quality in inexperienced volunteers. As well, the passive ventilation volumes were significantly increased and sustained when the device was used.
publisherThe American Society of Mechanical Engineers (ASME)
titleQuantification of Passive Ventilation Produced by Manual Chest Compressions Using a New Cardiopulmonary Resuscitation Feedback Device
typeJournal Paper
journal volume14
journal issue2
journal titleJournal of Medical Devices
identifier doi10.1115/1.4046512
page24503
treeJournal of Medical Devices:;2020:;volume( 014 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)