YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASCE
    • Journal of Materials in Civil Engineering
    • View Item
    •   YE&T Library
    • ASCE
    • Journal of Materials in Civil Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Study of Microstructural, Physical, Thermal, and Mechanical Properties of Organic Waste–Incorporated Fired Clay Bricks in the Framework of Energy Conservation

    Source: Journal of Materials in Civil Engineering:;2021:;Volume ( 033 ):;issue: 005::page 04021066-1
    Author:
    Farah Anjum
    ,
    Muhammad Yasin Naz
    ,
    Abdul Ghaffar
    ,
    Shazia Shukrullah
    ,
    Kashif Kamran
    ,
    Abdul Ghuffar
    DOI: 10.1061/(ASCE)MT.1943-5533.0003683
    Publisher: ASCE
    Abstract: This comparative study investigated the microstructural, thermophysical, and mechanical properties of tea waste–, sawdust-, and wheat husk–incorporated clay bricks. The bricks were prepared by missing clay with different amounts of organic wastes and firing at 600°C and 1,000°C. A transient plane source technique was used to measure the thermal properties of the fired bricks. The calorific values of the tested organic wastes were measured in the range of 15–17  MJ/kg. The maximum loss on ignition of tea waste–, sawdust-, and wheat husk–incorporated bricks was measured at about 14.94%, 13.75%, and 9.26%, respectively. The tea waste added–bricks exhibited the highest water absorbance, 20.8%–35.7%, among all the tested samples. The specific surface area of the tea waste–, sawdust-, and wheat husk–added bricks was measured at about 146.43, 139.47, and 167.25  m2/g, respectively. Similarly, the pore volume was measured at about 0.192, 0.184, and 0.219  cm3/g, respectively. When compared with a reference brick, the compressive strength decreased by 15%–59% for 2%–8% by weight of tea waste, by 12%–59% for 2%–10% by weight of sawdust, and 31%–69% for 1%–4% by weight of wheat husk in the brick. However, the compressive strength of the waste-added bricks was still in good agreement with Pakistan building code standards.
    • Download: (4.737Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Study of Microstructural, Physical, Thermal, and Mechanical Properties of Organic Waste–Incorporated Fired Clay Bricks in the Framework of Energy Conservation

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4269989
    Collections
    • Journal of Materials in Civil Engineering

    Show full item record

    contributor authorFarah Anjum
    contributor authorMuhammad Yasin Naz
    contributor authorAbdul Ghaffar
    contributor authorShazia Shukrullah
    contributor authorKashif Kamran
    contributor authorAbdul Ghuffar
    date accessioned2022-01-31T23:35:06Z
    date available2022-01-31T23:35:06Z
    date issued5/1/2021
    identifier other%28ASCE%29MT.1943-5533.0003683.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4269989
    description abstractThis comparative study investigated the microstructural, thermophysical, and mechanical properties of tea waste–, sawdust-, and wheat husk–incorporated clay bricks. The bricks were prepared by missing clay with different amounts of organic wastes and firing at 600°C and 1,000°C. A transient plane source technique was used to measure the thermal properties of the fired bricks. The calorific values of the tested organic wastes were measured in the range of 15–17  MJ/kg. The maximum loss on ignition of tea waste–, sawdust-, and wheat husk–incorporated bricks was measured at about 14.94%, 13.75%, and 9.26%, respectively. The tea waste added–bricks exhibited the highest water absorbance, 20.8%–35.7%, among all the tested samples. The specific surface area of the tea waste–, sawdust-, and wheat husk–added bricks was measured at about 146.43, 139.47, and 167.25  m2/g, respectively. Similarly, the pore volume was measured at about 0.192, 0.184, and 0.219  cm3/g, respectively. When compared with a reference brick, the compressive strength decreased by 15%–59% for 2%–8% by weight of tea waste, by 12%–59% for 2%–10% by weight of sawdust, and 31%–69% for 1%–4% by weight of wheat husk in the brick. However, the compressive strength of the waste-added bricks was still in good agreement with Pakistan building code standards.
    publisherASCE
    titleStudy of Microstructural, Physical, Thermal, and Mechanical Properties of Organic Waste–Incorporated Fired Clay Bricks in the Framework of Energy Conservation
    typeJournal Paper
    journal volume33
    journal issue5
    journal titleJournal of Materials in Civil Engineering
    identifier doi10.1061/(ASCE)MT.1943-5533.0003683
    journal fristpage04021066-1
    journal lastpage04021066-15
    page15
    treeJournal of Materials in Civil Engineering:;2021:;Volume ( 033 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian