    Genetic Algorithm Based Optimum Semi-Active Control of Building Frames Using Limited Number of Magneto-Rheological Dampers and Sensors

    Source: Journal of Dynamic Systems, Measurement, and Control:;2018:;volume( 140 ):;issue: 010::page 101013
    Author:
    Bhaiya, Vishisht
    ,
    Bharti, S. D.
    ,
    Shrimali, M. K.
    ,
    Datta, T. K.
    DOI: 10.1115/1.4040213
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Optimum semi-active control with a limited number of magneto-rheological (MR) dampers and measurement sensors has certain requirements. Most important of them is the accurate estimation of control forces developed in the MR dampers from the observations made in the structure. Therefore, the observation strategy should form an integral part of the optimization problem. The existing literature on the subject does not address this issue properly. The paper presents a computationally efficient optimization scheme for semi-active control of partially observed building frames using a limited number of MR dampers and sensors for earthquakes. The control scheme duly incorporates the locations of measurement sensors as variables into the genetic algorithm (GA) based optimization problem. A ten-storied building frame is taken as an illustrative example. The optimum control strategy utilizes two well-known control laws, namely, the linear quadratic Gaussian (LQG) with clipped optimal control and the bang-bang control to find the time histories of voltage to be applied to the MR dampers. The results of the numerical study show that the proposed scheme of sensor placement provides the optimum reduction of response with more computational efficiency. Second, optimal locations of sensors vary with the response quantities to be controlled, the nature of earthquake, and the control algorithm. Third, optimal locations of MR dampers are invariant of the response quantities to be controlled and the nature of earthquake.
    • Download: (3.627Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Genetic Algorithm Based Optimum Semi-Active Control of Building Frames Using Limited Number of Magneto-Rheological Dampers and Sensors

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4253888
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorBhaiya, Vishisht
    contributor authorBharti, S. D.
    contributor authorShrimali, M. K.
    contributor authorDatta, T. K.
    date accessioned2019-02-28T11:12:45Z
    date available2019-02-28T11:12:45Z
    date copyright5/28/2018 12:00:00 AM
    date issued2018
    identifier issn0022-0434
    identifier otherds_140_10_101013.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253888
    description abstractOptimum semi-active control with a limited number of magneto-rheological (MR) dampers and measurement sensors has certain requirements. Most important of them is the accurate estimation of control forces developed in the MR dampers from the observations made in the structure. Therefore, the observation strategy should form an integral part of the optimization problem. The existing literature on the subject does not address this issue properly. The paper presents a computationally efficient optimization scheme for semi-active control of partially observed building frames using a limited number of MR dampers and sensors for earthquakes. The control scheme duly incorporates the locations of measurement sensors as variables into the genetic algorithm (GA) based optimization problem. A ten-storied building frame is taken as an illustrative example. The optimum control strategy utilizes two well-known control laws, namely, the linear quadratic Gaussian (LQG) with clipped optimal control and the bang-bang control to find the time histories of voltage to be applied to the MR dampers. The results of the numerical study show that the proposed scheme of sensor placement provides the optimum reduction of response with more computational efficiency. Second, optimal locations of sensors vary with the response quantities to be controlled, the nature of earthquake, and the control algorithm. Third, optimal locations of MR dampers are invariant of the response quantities to be controlled and the nature of earthquake.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleGenetic Algorithm Based Optimum Semi-Active Control of Building Frames Using Limited Number of Magneto-Rheological Dampers and Sensors
    typeJournal Paper
    journal volume140
    journal issue10
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.4040213
    journal fristpage101013
    journal lastpage101013-13
    treeJournal of Dynamic Systems, Measurement, and Control:;2018:;volume( 140 ):;issue: 010
    contenttypeFulltext