    Experimental Performance Assessment of Nearly Full-Scale Reinforced Concrete Columns with Partially Debonded Longitudinal Reinforcement

    Source: Journal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 004
    Author:
    M. T. Nikoukalam
    ,
    P. Sideris
    DOI: 10.1061/(ASCE)ST.1943-541X.0001708
    Publisher: American Society of Civil Engineers
    Abstract: This paper presents an experimental study investigating the effect of partial debonding of longitudinal reinforcement at the location of the plastic hinge on the performance of reinforced concrete columns in special moment-resisting frames designed for seismic regions as per standard guidelines. Partial debonding is investigated as a means of spreading locally induced deformations over larger rebar lengths, thereby preventing early rebar yielding and fracture and improving the seismic performance of the columns. The experimental program, which was conducted at the University of Colorado Boulder, included quasi-static cyclic testing of three nearly full-scale (∼1∶1.14 or ∼88%) cantilever columns with various debonded reinforcement lengths. The experimental findings showed that reinforcement debonding resulted in early onset of concrete cracking and delayed reinforcement yielding. Spreading of concrete damage decreased with the debonded length, not exceeding half of the plastic hinge length (as opposed to the full plastic hinge length for bonded reinforcement). Debonding alleviated strain localizations in the steel reinforcement, at least, for drift ratios below 2%. The peak strength and initial elastic stiffness decreased with the debonded length. Energy dissipation and equivalent viscous damping ratio increased with the debonded length for drift ratios below 2%, and decreased with the debonded length for drift ratios exceeding 3%. Self-centering improved with the debonded length.
    • Download: (3.383Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Experimental Performance Assessment of Nearly Full-Scale Reinforced Concrete Columns with Partially Debonded Longitudinal Reinforcement

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/4237058
    Collections
    • Journal of Structural Engineering

    Show full item record

    contributor authorM. T. Nikoukalam
    contributor authorP. Sideris
    date accessioned2017-12-16T08:58:51Z
    date available2017-12-16T08:58:51Z
    date issued2017
    identifier other%28ASCE%29ST.1943-541X.0001708.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4237058
    description abstractThis paper presents an experimental study investigating the effect of partial debonding of longitudinal reinforcement at the location of the plastic hinge on the performance of reinforced concrete columns in special moment-resisting frames designed for seismic regions as per standard guidelines. Partial debonding is investigated as a means of spreading locally induced deformations over larger rebar lengths, thereby preventing early rebar yielding and fracture and improving the seismic performance of the columns. The experimental program, which was conducted at the University of Colorado Boulder, included quasi-static cyclic testing of three nearly full-scale (∼1∶1.14 or ∼88%) cantilever columns with various debonded reinforcement lengths. The experimental findings showed that reinforcement debonding resulted in early onset of concrete cracking and delayed reinforcement yielding. Spreading of concrete damage decreased with the debonded length, not exceeding half of the plastic hinge length (as opposed to the full plastic hinge length for bonded reinforcement). Debonding alleviated strain localizations in the steel reinforcement, at least, for drift ratios below 2%. The peak strength and initial elastic stiffness decreased with the debonded length. Energy dissipation and equivalent viscous damping ratio increased with the debonded length for drift ratios below 2%, and decreased with the debonded length for drift ratios exceeding 3%. Self-centering improved with the debonded length.
    publisherAmerican Society of Civil Engineers
    titleExperimental Performance Assessment of Nearly Full-Scale Reinforced Concrete Columns with Partially Debonded Longitudinal Reinforcement
    typeJournal Paper
    journal volume143
    journal issue4
    journal titleJournal of Structural Engineering
    identifier doi10.1061/(ASCE)ST.1943-541X.0001708
    treeJournal of Structural Engineering:;2017:;Volume ( 143 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian