    Archive

    Critique of Floating‐Dome Technique for Estimating Reaeration Rates

    Source: Journal of Environmental Engineering:;1991:;Volume ( 117 ):;issue: 001
    Author:
    T. V. Belanger
    ,
    E. A. Korzun
    DOI: 10.1061/(ASCE)0733-9372(1991)117:1(144)
    Publisher: American Society of Civil Engineers
    Abstract: Analysis of the floating-dome reaeration measurement technique by comparing dome oxygen-exchange rates and actual free-exchange rates indicates that the technique results in erroneous values. Significant temperature changes in the dome, which are common and do not represent the atmosphere-water interfacial region, introduce calculation errors not compensated for in the methodology. Additionally, the dome protects the water surface and reduces the contribution of wind-induced turbulence, a significant factor in reaeration. Based on these facts, it appears the dome technique is not an accurate or useful method for reaeration measurements.
    • Download: (429.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Critique of Floating‐Dome Technique for Estimating Reaeration Rates

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/39019
    Collections
    • Journal of Environmental Engineering

    Show full item record

    contributor authorT. V. Belanger
    contributor authorE. A. Korzun
    date accessioned2017-05-08T21:06:37Z
    date available2017-05-08T21:06:37Z
    date copyrightJanuary 1991
    date issued1991
    identifier other%28asce%290733-9372%281991%29117%3A1%28144%29.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/39019
    description abstractAnalysis of the floating-dome reaeration measurement technique by comparing dome oxygen-exchange rates and actual free-exchange rates indicates that the technique results in erroneous values. Significant temperature changes in the dome, which are common and do not represent the atmosphere-water interfacial region, introduce calculation errors not compensated for in the methodology. Additionally, the dome protects the water surface and reduces the contribution of wind-induced turbulence, a significant factor in reaeration. Based on these facts, it appears the dome technique is not an accurate or useful method for reaeration measurements.
    publisherAmerican Society of Civil Engineers
    titleCritique of Floating‐Dome Technique for Estimating Reaeration Rates
    typeJournal Paper
    journal volume117
    journal issue1
    journal titleJournal of Environmental Engineering
    identifier doi10.1061/(ASCE)0733-9372(1991)117:1(144)
    treeJournal of Environmental Engineering:;1991:;Volume ( 117 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian