description abstractAnalysis of the floating-dome reaeration measurement technique by comparing dome oxygen-exchange rates and actual free-exchange rates indicates that the technique results in erroneous values. Significant temperature changes in the dome, which are common and do not represent the atmosphere-water interfacial region, introduce calculation errors not compensated for in the methodology. Additionally, the dome protects the water surface and reduces the contribution of wind-induced turbulence, a significant factor in reaeration. Based on these facts, it appears the dome technique is not an accurate or useful method for reaeration measurements.
publisherAmerican Society of Civil Engineers
titleCritique of Floating‐Dome Technique for Estimating Reaeration Rates
typeJournal Paper
journal volume117
journal issue1
journal titleJournal of Environmental Engineering
identifier doi10.1061/(ASCE)0733-9372(1991)117:1(144)
treeJournal of Environmental Engineering:;1991:;Volume ( 117 ):;issue: 001