Metal Railing Systems for Buildings: Design versus Experimental DataSource: Journal of Structural Engineering:;1991:;Volume ( 117 ):;issue: 002Author:E. George Stern
DOI: 10.1061/(ASCE)0733-9445(1991)117:2(515)Publisher: American Society of Civil Engineers
Abstract: A large number of railing systems was tested—pipe, panel, and picket railing systems made of steel, aluminum, red brass, yellow brass, and stainless steel, and fabricated of solid, pipe, and tubular members of square, rectangular, channel, and molded shapes. The predicted design loads were compared with experimental data. The normal design procedure that assumes transfer of loads by the top rail to the posts was found sufficiently accurate for the railing systems under investigation. The deflection limitations recommended in ASTM Standard E 985 were found to be more stringent than the established strength requirements, as is indicated by the strength ratios of 1.7 and 2.4 for the allowable deflection and the observed maximum test load, respectively. Designers of railing systems and code authorities should give consideration to the serviceability of these building components in the light of the stringent deflection criteria based on standards of acceptance and overall safety.
|
Collections
Show full item record
| contributor author | E. George Stern | |
| date accessioned | 2017-05-08T20:54:04Z | |
| date available | 2017-05-08T20:54:04Z | |
| date copyright | February 1991 | |
| date issued | 1991 | |
| identifier other | %28asce%290733-9445%281991%29117%3A2%28515%29.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/31055 | |
| description abstract | A large number of railing systems was tested—pipe, panel, and picket railing systems made of steel, aluminum, red brass, yellow brass, and stainless steel, and fabricated of solid, pipe, and tubular members of square, rectangular, channel, and molded shapes. The predicted design loads were compared with experimental data. The normal design procedure that assumes transfer of loads by the top rail to the posts was found sufficiently accurate for the railing systems under investigation. The deflection limitations recommended in ASTM Standard E 985 were found to be more stringent than the established strength requirements, as is indicated by the strength ratios of 1.7 and 2.4 for the allowable deflection and the observed maximum test load, respectively. Designers of railing systems and code authorities should give consideration to the serviceability of these building components in the light of the stringent deflection criteria based on standards of acceptance and overall safety. | |
| publisher | American Society of Civil Engineers | |
| title | Metal Railing Systems for Buildings: Design versus Experimental Data | |
| type | Journal Paper | |
| journal volume | 117 | |
| journal issue | 2 | |
| journal title | Journal of Structural Engineering | |
| identifier doi | 10.1061/(ASCE)0733-9445(1991)117:2(515) | |
| tree | Journal of Structural Engineering:;1991:;Volume ( 117 ):;issue: 002 | |
| contenttype | Fulltext |