Show simple item record

contributor authorE. George Stern
date accessioned2017-05-08T20:54:04Z
date available2017-05-08T20:54:04Z
date copyrightFebruary 1991
date issued1991
identifier other%28asce%290733-9445%281991%29117%3A2%28515%29.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/31055
description abstractA large number of railing systems was tested—pipe, panel, and picket railing systems made of steel, aluminum, red brass, yellow brass, and stainless steel, and fabricated of solid, pipe, and tubular members of square, rectangular, channel, and molded shapes. The predicted design loads were compared with experimental data. The normal design procedure that assumes transfer of loads by the top rail to the posts was found sufficiently accurate for the railing systems under investigation. The deflection limitations recommended in ASTM Standard E 985 were found to be more stringent than the established strength requirements, as is indicated by the strength ratios of 1.7 and 2.4 for the allowable deflection and the observed maximum test load, respectively. Designers of railing systems and code authorities should give consideration to the serviceability of these building components in the light of the stringent deflection criteria based on standards of acceptance and overall safety.
publisherAmerican Society of Civil Engineers
titleMetal Railing Systems for Buildings: Design versus Experimental Data
typeJournal Paper
journal volume117
journal issue2
journal titleJournal of Structural Engineering
identifier doi10.1061/(ASCE)0733-9445(1991)117:2(515)
treeJournal of Structural Engineering:;1991:;Volume ( 117 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record